Parameters
Basic settings
56
Controller BUS 6 T
5.94017.06
Baumüller Nürnberg GmbH
Motorgeber-Strichzahl (number of motor encoder scale marks)
The resolution for rotation feedback 1 (motor encoder) represents the pulses per motor
revolution.
number of motor pole pairs (p)
The number of motor pole pairs is set via this parameter.
nominal motor speed (n
N
)
Via this parameter you specifiy the speed at which the motor reaches nominal power.
slip frequency at nominal speed (f
2N
)
The slip frequency entry is only necessary for asynchronous motors.
maximum motor speed (n
max
)
The manufacturer specifies the maximum motor speed in the motor data sheet.
set EMF value(E
N
)
This parameter specifies the motor's nominal EMF value.