integral-action time adaptation
Below the lower adaptation limit the integral-action time adaptation indicates the percentage
value referring to the speed controller integral-action time (ID no. 101). Above the upper
adaptation limit the speed controller proportional gain changes linearly taking the adaptation
of the integral-action time and the current speed into account.
set velocity window KI counter N_I_component)
The KI counter is set at a preset difference between set speed value and actual speed
value.
If this parameter is set to 1000 rpm, the speed controller's integral-action component is not
deleted.
delete velocity window N_I_component
This parameter specifies the difference between set speed value and actual speed value at
which the KI counter is counted back and the speed controller's integral-action component
deleted.
actual speed value time constant
For smoothing the actual speed value a time constant can be set here.