Parameters
Parameter set 0
82
Controller BUS 6 T
5.94017.06
Baumüller Nürnberg GmbH
7.4.4 Messages - monitoring
Parameter overview
ID no.
Name
Range
min. ... max.
Unit
Standard
value
Display
only
messages - monitoring
124
speed threshold n
min
6.0000 ... 600.0000
rpm
100
157
velocity window
6.0000 ... 600.0000
rpm
120
125
velocity threshold n
x
6.0000 ... 1200.0000
rpm
100
32829
velocity threshold n
max
1200.0000 ... 12000.0000
rpm
32831
maximum intermediate circuit voltage
threshold
20 ... 800
V
126
torque threshold M
dx
10.0 ... 100.0
%
32830
response time Pzkx (M
dx
)
0.100 ... 30.000
s
32931
voltage failure time
0.000 ... 60.000
s
0
Parameter description
speed threshold n
min
The zero-speed window describes the velocity deviation from n = 0 as an absolute value.
If the actual velocity value is inside the zero-speed window the drive sets the message
n
act
= 0 (ID no. 331).
Display via LED H403 yellow or via relay contacts X3:9 and X3:10 on printed circuit board
3.9211.
velocity window
The drive sets the velocity-dependent messages whenever the measured velocity value
exceeds or falls below the respective velocity comparison value and is inside the velocity
window.
velocity threshold n
x
If the actual velocity value falls below the velocity threshold n
x
, the drive sets the message
n
act
< n
x
(ID no. 332) in Class 3 Diagnostics.
velocity threshold n
max
The maximum permissible ve 10 % is set via this parameter. On exceeding the
threshold the controller is inhibited and and the Class 1 Diagnostics error message set.
maximum intermediate circuit voltage threshold
This parameter is set to the maximum intermediate circuit voltage as standard. On
exceeding the maximum threshold, pulse inhibit takes place.
Summary of Contents for BUS 6-T Series
Page 6: ...Abbreviations IV Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 10: ...Technical data 4 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 18: ...Assembly 12 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 22: ...Installation 16 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 40: ...Commissioning 34 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 52: ...Commissioning Torque control 46 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH PC unit ...