Parameter set 2
Parameters
Controller BUS 6 T
87
Baumüller Nürnberg GmbH
5.94017.06
7.6.3 Speed controller
Parameter overview
ID no.
Name
Range
min. ... max.
Unit
Standard
value
Display
only
speed controller
8292
speed controller gain
0.10 ... 400.00
8293
speed controller integral-action time
0.00 ... 655.00
ms
8401
lower adaptation limit for speed
controller
0 ... 0
rpm
0
8402
upper adaptation limit for speed
controller
10.0000 ... 1000.0000
rpm
200
8403
proportional gain adaptation
10.0 ... 1000.0
%
8404
integral-action time adaptation
1.0 ... 100.0
%
41121
set velocity window KI counter
N_I_component)
1.0000 ... 600.0000
rpm
41122
delete velocity window N_I_component
1.0000 ... 600.0000
rpm
41124
actual speed value time constant
0.0 ... 60.0
ms
0
7.6.4 Messages - monitoring
Parameter overview
ID no.
Name
Range
min. ... max.
Unit
Standard
value
Display
only
messages - monitoring
8316
speed threshold n
min
6.0000 ... 600.0000
rpm
100
8349
velocity window
6.0000 ... 600.0000
rpm
120
8317
velocity threshold nx
6.0000 ... 1200.0000
rpm
100
41021
velocity threshold nmax
1200.0000 ... 12000.0000
rpm
41023
maximum intermediate circuit voltage
threshold
20 ... 800
V
8318
torque threshold Mdx
10.0 ... 100.0
%
90
41022
response time Pzkx (Mdx)
0.100 ... 30.000
s
0.5
Parameter description
Parameter description see parameter set 0.
Summary of Contents for BUS 6-T Series
Page 6: ...Abbreviations IV Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 10: ...Technical data 4 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 18: ...Assembly 12 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 22: ...Installation 16 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 40: ...Commissioning 34 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 52: ...Commissioning Torque control 46 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH PC unit ...