Parameter set 1
Parameters
Controller BUS 6 T
85
Baumüller Nürnberg GmbH
5.94017.06
7.5.3 Speed controller
Parameter overview
ID no.
Name
Range
min. ... max.
Unit
Standard
value
Display
only
speed controller
4196
speed controller gain
0.10 ... 400.00
4197
speed controller integral-action time
0.00 ... 655.00
ms
4305
lower adaptation limit for speed
controller
0 ... 0
rpm
0
4306
upper adaptation limit for speed
controller
10.0000 ... 1000.0000
rpm
200
4307
proportional gain adaptation
100.0 ... 1000.0
%
4308
integral-action time adaptation
1.0 ... 100.0
%
37025
set velocity window KI counter
N_I_component)
1.0000 ... 600.0000
rpm
37026
delete velocity window N_I_component
1.0000 ... 600.0000
rpm
37028
actual speed value time constant
0.0 ... 60.0
ms
0
7.5.4 Messages - monitoring
Parameter overview
ID no.
Name
Range
min. ... max.
Unit
Standard
value
Display
only
messages - monitoring
4220
speed threshold n
min
6.0000 ... 600.0000
rpm
100
4253
velocity window
6.0000 ... 600.0000
rpm
120
4221
velocity threshold n
x
6.0000 ... 1200.0000
rpm
100
36925
velocity threshold n
max
1200.0000 ... 12000.0000
rpm
36927
maximum intermediate circuit voltage
threshold
20 ... 800
V
4222
torque threshold M
dx
10.0 ... 100.0
%
90
36926
response time Pzkx (M
dx
)
0.100 ... 30.000
s
0.5
Parameter description
Parameter description see parameter set 0.
Summary of Contents for BUS 6-T Series
Page 6: ...Abbreviations IV Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 10: ...Technical data 4 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 18: ...Assembly 12 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 22: ...Installation 16 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 40: ...Commissioning 34 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 52: ...Commissioning Torque control 46 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH PC unit ...