Parameters
Parameter set 3
88
Controller BUS 6 T
5.94017.06
Baumüller Nürnberg GmbH
7.7 Parameter set 3
7.7.1 Velocity and ramp function generator
Parameter overview
ID no.
Name
Range
min. ... max.
Unit
Standard
value
Display
only
velocity and ramp function generator
12324
set velocity value
-12000.0000 ... 12000.0000
rpm
0
(
)
12331
polarity of set velocity value
0
12326
positive velocity limit value
0.0000 ... 12000.0000
rpm
12327
negative velocity limit value
0.0000 ... 12000.0000
rpm
12379
bipolar velocity limit value
0.0000 ... 12000.0000
rpm
40
actual velocity value
-12000.0000 ... 12000.0000
rpm
45113
ramp function generator
0 ... 1
0
45114
ramp-up time
0.010 ... 60.000
s
0.01
45115
ramp-down time
0.010 ... 60.000
s
0.01
7.7.2 Rounding generator and torque
Parameter overview
ID no.
Name
Range
min. ... max.
Unit
Standard
value
Display
only
rounding generator and torque
45111
rounding generator
0 ... 1
0
45112
rounding generator time
10.0 ... 6000.0
ms
10
12368
set torque value for M control
-100.0 ... 100.0
%
0
12373
polarity of set torque value
0
12370
positive torque limit value
0.0 ... 100.0
%
100
(
)
12371
negative torque limit value
-100.0 ... 0
%
-100
(
)
12380
bipolar torque limit value
0.0 ... 100.0
%
100
(
)
84
actual torque value
-100.0 ... 100.0
%
Summary of Contents for BUS 6-T Series
Page 6: ...Abbreviations IV Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 10: ...Technical data 4 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 18: ...Assembly 12 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 22: ...Installation 16 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 40: ...Commissioning 34 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 52: ...Commissioning Torque control 46 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH PC unit ...