Display and measuring parameters
Parameters
Controller BUS 6 T
69
Baumüller Nürnberg GmbH
5.94017.06
7.3.5 Measuring channel 1 and 2
Parameter overview
ID no.
Name
Range
min. ... max.
Unit
Standard
value
Display
only
measuring channel 1 und 2
32768
measuring channel 1
1 ... 32916
32770
offset of measuring channel 1
-2047 ... +2047
0
32769
scaling exponent of measuring
channel 1
-16 ... +16
0
32772
measuring channel 2
1 ... 32916
32774
offset of measuring channel 2
-2047 ... +2047
0
32773
scaling exponent of measuring
channel 2
-16 ... +16
0
32777
value 1 (32 bit)
32778
value 2 (16 bit)
32867
pulse enabled
0 ... 65535
32868
controller enabled
0 ... 65535
Parameter description
measuring channel 1
Any parameter can be assigned to measuring channel 1. Output (-10 V ... + 10 V) plug
X22:11, ground X22:12.
offset of measuring channel 1
This value serves for the offset compensation of the converters and differential amplifiers.
scaling exponent of measuring channel 1
Via this parameter exponential alteration of the gain is possible. The output is limited as of
±
10 V.
measuring channel 2
Any parameter can be assigned to measuring channel 2. Output (-10 V ... + 10 V) plug
X22:15, ground X22:15.
offset of measuring channel 2
This value serves for the offset compensation of the converters and differential amplifiers.
scaling exponent of measuring channel 2
Via this parameter exponential alteration of the gain is possible. The output is limited as of
±
10 V.
Summary of Contents for BUS 6-T Series
Page 6: ...Abbreviations IV Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 10: ...Technical data 4 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 18: ...Assembly 12 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 22: ...Installation 16 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 40: ...Commissioning 34 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 52: ...Commissioning Torque control 46 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH PC unit ...