Basic settings
Parameters
Controller BUS 6 T
59
Baumüller Nürnberg GmbH
5.94017.06
set magnetising current value (I
α
αα
α
N
)
The magnetising current value is always 0 by synchronous motors.
magnetising current limitation (I
α
αα
α
G
)
The maximum value of the magnetising current is entered via these parameters.
Sychronous motors:
typical value 5 A ... 20 A
Asynchronous motors:
1.2 x set magnetising current value (ID no. 32814)
set active current value (I
ββββ
N
)
I
I
I
N
N
N
β
α
=
−
2
2
active current limitation (I
ββββ
G
)
The active current limitation is entered via this parameter.
Asynchronous motors:
1.2 x set active current value (ID no. 32804)
time constant of actual torque value
This parameter specifies the time constant of the actual torque value.
Typical value 1 ms ... 3 ms.
set apparent current value(I
N
)
apparent current limitation(I
NG
)
This parameter displays the set value and the limitation of the apparent current.
torque controller gain
torque controller integral-action time
These parameters indicate the torque controller's gain and its integral-action time.
flux controller gain
flux controller integral-action time
These parameters specify the flux controller's gain and its integral-action time.
Summary of Contents for BUS 6-T Series
Page 6: ...Abbreviations IV Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 10: ...Technical data 4 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 18: ...Assembly 12 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 22: ...Installation 16 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 40: ...Commissioning 34 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 52: ...Commissioning Torque control 46 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH PC unit ...