Maintenance
Status messages
108
Controller BUS 6 T
5.94017.06
Baumüller Nürnberg GmbH
BUS warning
Bit no.
Meaning
0
1: error encoder evaluation 1
1
1: error encoder evaluation 2
2 ... 15
reserved
supply warning
Bit no.
Meaning
0
1: BUS warning
1 ... 15
reserved
Class 3 Diagnostics
Operating status messages. Class 3 Diagnostics is read via the service channel. The bits
set in Class 3 Diagnostics are additionally defined by ID numbers.
Bit no.
Meaning
0
1: n
act
= n
set
1
1: n
act
< n
min
2
1: n
act
< n
x
3
1: M
d
> M
dx
4
1: M
d
> M
dlimit
5
1: n
soll
> N
limit
6
1: in position
7
1: P > P
x
8 ... 14
reserved
15
1: bit set in Manufacturer Class 3 Diagnostics
Manufacturer Class 3 Diagnostics
In Manufacturer Class 3 Diagnostics the manufacturer of the drive can define additional
shutdown advance warnings. If a warning is set or deleted in Manufacturer Class 3
Diagnostics, this leads to the setting of the manufacturer-specific warning in Class 3
Diagnostics.
Bit no.
Meaning
0
1: BUS operating message
1
1:BUS hardware message
2 ... 7
always 0
8
1: BUG supply message
9 ... 15
always 0
Manufacturer Class 3 Diagnostics is read via the service channel.
Summary of Contents for BUS 6-T Series
Page 6: ...Abbreviations IV Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 10: ...Technical data 4 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 18: ...Assembly 12 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 22: ...Installation 16 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 40: ...Commissioning 34 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 52: ...Commissioning Torque control 46 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH PC unit ...