Status messages
Maintenance
Controller BUS 6 T
105
Baumüller Nürnberg GmbH
5.94017.06
supply operating error
An operating error of the supply leads to pulse inhibit of the controller.
Bit no.
Meaning
0
always 0
1
1: supply not ready for use
BUG hardware error
A hardware error leads to pulse inhibit of the controller.
Bit no.
Meaning
0
reserved
1
1: supply not ready for use
error bar of I/O component boot
If an error occurs during the controller's boot procedure this error bar is activated and
controller enabling is not possible (controller inhibit).
NOTE
This ID no. can only be read by activation of key F4 on PC. Only the LED´s „Power“ (green)
and „controller inhibit“ (red) light on the unit.
Bit no.
Meaning
0
1: error of internal RAM
1
1: error of external RAM
2
1: memory submodule EPROM not available
3
1: memory submodule EEPROM faulty
4
1: memory submodule EEPROM not available
5
1: timeout at upper A/D converter
6
1: timeout at lower A/D converter
7
1: timeout at upper A/D converter
8
1: timeout at lower A/D converter
9
1: offset error at lower A/D converter
10
1: offset error at upper A/D converter
11
1: encoder module 1 not available
12
1: encoder module 2 not available
13
1: option board 1 not available
14
1: option board 2 not available
15
1: option board 3 not available
Summary of Contents for BUS 6-T Series
Page 6: ...Abbreviations IV Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 10: ...Technical data 4 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 18: ...Assembly 12 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 22: ...Installation 16 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 40: ...Commissioning 34 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 52: ...Commissioning Torque control 46 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH PC unit ...