Basic settings
Parameters
Controller BUS 6 T
53
Baumüller Nürnberg GmbH
5.94017.06
controller inhibit type
This parameter specifies the type of controller inhibit after slowing down the motor.
Value
Meaning
0
brake down
pulse inhibit when n=0
1
brake down
no pulse inhibit when n=0
NOTE
In operation mode position control after pulse enabling and controller enabling is given, the position
control enabling signal must be given delayed a minimum time of t
E
= 3 *
τ
R
, because the speed
controller is enabled after this time.