Maintenance
Status messages
102
Controller BUS 6 T
5.94017.06
Baumüller Nürnberg GmbH
Manufacturer Class 1 Diagnostics
Display of drive interlocking. A Class 1 Diagnostics error situation detected by the drive
leads to:
•
controller inhibit with brake down or pulse inhibit
•
setting of error bit.
Bit no.
Meaning
0
1: operating error BUS (PI or CI)
1
1: hardware error BUS (PI)
2
1: software error BUS (PI)
3 ... 7
reserved
8
1: operating error BUG supply (PI)
9
1: hardware error BUG supply (PI)
10 ... 15
reserved
PI (pulse inhibit)
CI (controller inhibit)
Delete the error bit (after remedying the fault) with the reset command (ID no. 99). When
switching on again a reset signal is automatically generated.
command "reset Class 1 Diagnostics"
If the drive receives this command via the service channel, Class 1 Diagnostics,
Manufacturer Class 1 Diagnostics and drive interlocking are deleted provided no more
errors are present.
The current error messages are deleted via the command
and
.
If an error in the BUG supply is present, the error must be deleted by switching the entire
supply voltage off and then on again (wait for the intermediate circuit capacitors to
discharge).
Additionally this command can be activated with digital input X22:3 (+24 V necessary).
Bit no.
Meaning
0
0: delete command in drive
1: set command in drive
1
0: interrupt command execution
1: enable command execution
2 ... 15
reserved
Summary of Contents for BUS 6-T Series
Page 6: ...Abbreviations IV Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 10: ...Technical data 4 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 18: ...Assembly 12 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 22: ...Installation 16 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 40: ...Commissioning 34 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 52: ...Commissioning Torque control 46 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH PC unit ...