Parameter set 3
Parameters
Controller BUS 6 T
89
Baumüller Nürnberg GmbH
5.94017.06
7.7.3 Speed controller
Parameter overview
ID no.
Name
Range
min. ... max.
Unit
Standard
value
Display
only
speed controller
12388
speed controller gain
1.00 ... 400.00
12389
speed controller integral-action time
4.00 ... 655.00
ms
12497
lower adaptation limit for speed
controller
0 ... 0
rpm
0
12498
upper adaptation limit for speed
controller
10.0000 ... 1000.0000
rpm
200
12499
proportional gain adaptation
100.0 ... 1000.0
%
12500
integral-action time adaptation
1.0 ... 100.0
%
45217
set velocity window KI counter
N_I_component)
1.0000 ... 600.0000
rpm
45218
delete velocity window N_I_component
1.0000 ... 600.0000
rpm
45220
actual speed value time constant
0.0 ... 60.0
ms
0
7.7.4 Messages - monitoring
Parameter overview
ID no.
Name
Range
min. ... max.
Unit
Standard
value
Display
only
messages - monitoring
12412
speed threshold n
min
6.0000 ... 600.0000
rpm
100
12445
velocity window
6.0000 ... 600.0000
rpm
120
12413
velocity threshold n
x
6.0000 ... 1200.0000
rpm
100
45117
velocity threshold n
max
1200.0000 ... 12000.0000
rpm
45119
maximum intermediate circuit voltage
threshold
20 ... 800
V
12414
torque threshold M
dx
10.0 ... 100.0
%
90
45118
response time Pzkx (M
dx
)
0.100 ... 30.000
s
0.5
Parameter description
Parameter description see parameter set 0.
Summary of Contents for BUS 6-T Series
Page 6: ...Abbreviations IV Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 10: ...Technical data 4 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 18: ...Assembly 12 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 22: ...Installation 16 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 40: ...Commissioning 34 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH ...
Page 52: ...Commissioning Torque control 46 Controller BUS 6 T 5 94017 06 Baumüller Nürnberg GmbH PC unit ...