Installation
UMSITRPDS3-1
November
2010
4-2
4.2 ENVIRONMENTAL CONSIDERATIONS
Many industrial processes create severe environmental conditions. The conditions at each transmitter
location must be within the specifications stated in Section 9.3 Specifications.
Although the transmitter is designed to perform in harsh conditions, it is prudent to choose a location that
minimizes the effects of heat, vibration, shock, and electrical interference.
CAUTION
Exceeding the specified operating temperature limits can adversely affect
performance and may damage the instrument. See the rating plate and Section 9
Model Designations and Specifications for temperature and other environmental
ratings.
4.3 PRE-INSTALLATION CONSIDERATIONS AND CALCULATIONS
These sub-sections provide pre-installation considerations and calculations that are needed to ensure
successful mechanical and electrical installations.
4.3.1 Mechanical
•
Select the application. Series DSIII transmitters are suitable for, but not limited to:
•
Flow measurement
•
Gauge pressure measurement
•
Level measurement
•
Draft pressure measurement
•
Absolute pressure measurement
•
High differential pressure measurement
•
Hydrostatic tank gauging measurement
•
Determine the physical mounting of the transmitter. Consider:
•
Application – See Figures 4-1 through 4-5. Mounting position for a specific application can be
important to system performance.
•
Optional brackets for pipe mounting or surface mounting
•
Pipe or tank wall thickness, diameter, rigidity, and freedom from vibration
•
Clearance for transmitter installation and maintenance
•
Need to rotate the enclosure and display for viewing ease
Refer to Figures 9-1 through 9-4 for transmitter dimensions and to the figures in Sections 4.4 and 4.5
for typical mechanical installations. Refer to Section 9.3 for mechanical and environmental
specifications.
Содержание 7MF4033 series
Страница 48: ...Model 275 Universal Hart Communicator UMSITRPDS3 1 November 2010 2 26 ...
Страница 86: ...Installation UMSITRPDS3 1 November 2010 4 34 ...
Страница 152: ...Calibration and Maintenance UMSITRPSD3 1 November 2010 7 20 ...
Страница 158: ...Circuit Description UMSITRPDS3 1 November 2010 8 6 ...
Страница 197: ......
Страница 198: ......
Страница 200: ...Model Designations and Specifications UMSITRPDS3 1 November 2010 9 42 ...
Страница 204: ...Glossary UMSITRPDS3 1 November 2010 10 4 ...
Страница 208: ...Appendix A Online Configuration Map UMSITRPDS3 1 11 4 November 2010 ...
Страница 210: ...Appendix B Hazardous Area Installation UMSITRPDS3 1 12 2 November 2010 FIGURE 12 1 Control Drawing ...
Страница 211: ...UMSITRPDS3 1 Appendix B Hazardous Area Installation November 2010 12 3 FIGURE 12 2 Control Drawing ...
Страница 212: ...Appendix B Hazardous Area Installation UMSITRPDS3 1 12 4 November 2010 FIGURE 12 3 Control Drawing ...
Страница 216: ...Appendix C Elevation and Suppression Correction UMSITRPDS3 1 13 4 November 2010 ...