Bits
Description
[23]
BUSY
Busy/Idle(Read Only)
0 = EADC is in idle state.
1 = EADC is busy at conversion.
[22:21]
Reserved
Reserved. Any values read should be ignored. When writing to this field always write with
reset value.
[20:16]
CHANNEL
Current Conversion Channel(Read Only)
This filed reflects ADC current conversion channel when BUSY=1.
It is read only.
00H = EADC0_CH0.
01H = EADC0_CH1.
02H = EADC0_CH2.
03H = EADC0_CH3.
04H = EADC0_CH4.
05H = EADC0_CH5.
06H = EADC0_CH6.
07H = EADC0_CH7.
08H = EADC0_CH8.
09H = EADC0_CH9.
0AH = EADC0_CH10.
0BH = EADC0_CH11.
0CH = EADC0_CH12.
[15]
ADCMPO3
ADC Compare 3 Output Status(Read Only)
The 12 bits compare3 data CMPDAT3 (EADC_CMP3[27:16]) is used to compare with
conversion result of specified sample module. User can use it to monitor the external
analog input pin voltage status.
0 = Conversion result in EADC_DAT less than CMPDAT3 setting.
1 = Conversion result in EADC_DAT great than or equal CMPDAT3 setting.
[14]
ADCMPO2
ADC Compare 2 Output Status(Read Only)
The 12 bits compare2 data CMPDAT2 (EADC_CMP2[27:16]) is used to compare with
conversion result of specified sample module. User can use it to monitor the external
analog input pin voltage status.
0 = Conversion result in EADC_DAT less than CMPDAT2 setting.
1 = Conversion result in EADC_DAT great than or equal CMPDAT2 setting.
[13]
ADCMPO1
ADC Compare 1 Output Status(Read Only)
The 12 bits compare1 data CMPDAT1 (EADC_CMP1[27:16]) is used to compare with
conversion result of specified sample module. User can use it to monitor the external
analog input pin voltage status.
0 = Conversion result in EADC_DAT less than CMPDAT1 setting.
1 = Conversion result in EADC_DAT great than or equal CMPDAT1 setting.
[12]
ADCMPO0
ADC Compare 0 Output Status(Read Only)
The 12 bits compare0 data CMPDAT0 (EADC_CMP0[27:16]) is used to compare with
conversion result of specified sample module. User can use it to monitor the external
analog input pin voltage status.
0 = Conversion result in EADC_DAT less than CMPDAT0 setting.
1 = Conversion result in EADC_DAT great than or equal CMPDAT0 setting.
Содержание ISD94100 Series
Страница 528: ...ISD94100 Series Technical Reference Manual Sep 9 2019 Page 528 of 928 Rev1 09 ISD94100 SERIES TECHNICAL REFERENCE MANUAL...
Страница 626: ...ISD94100 Series Technical Reference Manual Sep 9 2019 Page 626 of 928 Rev1 09 ISD94100 SERIES TECHNICAL REFERENCE MANUAL...
Страница 702: ...ISD94100 Series Technical Reference Manual Sep 9 2019 Page 702 of 928 Rev1 09 ISD94100 SERIES TECHNICAL REFERENCE MANUAL...
Страница 875: ...ISD94100 Series Technical Reference Manual Sep 9 2019 Page 875 of 928 Rev1 09 ISD94100 SERIES TECHNICAL REFERENCE MANUAL...