3 - 17
MELSEC-A
3 SPECIFICATIONS AND FUNCTIONS
3.5.3 List of input signal details
The details of each AD75 external device connection connector (for 1 axis) signal are
shown below.
Signal name
Pin No.
Signal details
Common
36
35
•
Common for near-point dog signal, upper/lower limit, stop signal,
speed/position changeover signal, and external start signal.
Manual pulse generator
(B phase –)
Manual pulse generator
(A phase –)
28
27
Manual pulse generator
(B phase +)
Manual pulse generator
(A phase +)
10
9
•
Input the pulse signal from the manual pulse generator A phase and B
phase.
•
If the A phase is advanced more than the B phase, the positioning
address will increase at the rising edge and falling edge of each phase.
•
If the B phase is advanced more than the A phase, the positioning
address will decrease at the rising edge and falling edge of each phase.
[When increased] [When decreased]
+1+1+1+1+1+1+1+1
-1 -1 -1 -1 -1 -1 -1 -1
A phase
B phase
Positioning
address
A phase
B phase
Positioning
address
External start signal
16
•
Use as the positioning start, speed change request and skip request
input signal from an external source.
•
Set which function to use the external start signal with in " Pr.43
External start function selection".
Speed/position changeover signal
15
•
Input the control changeover signal for the speed/position changeover
control.
Stop signal
14
•
Input when positioning is stopped.
•
When this signal turns ON, the AD75 will stop the positioning being
executed.
After that, even if this signal turns from ON for OFF, the system will not
start.
Lower limit signal
13
•
This signal is input from the limit switch installed at the stroke lower limit
position.
•
Positioning will stop when this signal turns OFF.
•
When zero point return retry function is valid, this will be the lower limit
for finding the near-point dog signal.
Upper limit signal
12
•
This signal is input from the limit switch installed at the stroke upper limit
position.
•
Positioning will stop when this signal turns OFF.
•
When zero point return retry function is valid, this will be the upper limit
for finding the near-point dog signal.
Near-point dog signal
11
•
Use this for detecting the near-point dog during machine zero point
return.
•
The near-point dog signal is detected at turning from OFF to ON.
Содержание A1SD75M1
Страница 2: ......
Страница 20: ...A 18 MEMO...
Страница 22: ...MEMO...
Страница 27: ...1 5 MELSEC A 1 PRODUCT OUTLINE MEMO...
Страница 42: ...1 20 MELSEC A 1 PRODUCT OUTLINE MEMO...
Страница 52: ...2 10 MELSEC A 2 SYSTEM CONFIGURATION MEMO...
Страница 111: ...5 21 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 115: ...5 25 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 123: ...5 33 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 127: ...5 37 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 167: ...5 77 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 193: ...5 103 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 276: ...5 186 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 332: ...7 18 MELSEC A 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Страница 334: ...MEMO...
Страница 422: ...9 64 MELSEC A 9 MAIN POSITIONING CONTROL MEMO...
Страница 446: ...10 24 MELSEC A 10 ADVANCED POSITIONING CONTROL MEMO...
Страница 472: ...11 26 MELSEC A 11 MANUAL CONTROL MEMO...
Страница 576: ...12 104 MELSEC A 12 CONTROL AUXILIARY FUNCTIONS MEMO...
Страница 673: ...Appendix 5 MELSEC A APPENDICES Axis address mm inch degree pulse Axis address mm inch degree pulse...
Страница 679: ...Appendix 11 MELSEC A APPENDICES Initial value Axis 1 Axis 2 Axis 3 Remarks 0 0 0 1 1 0 0 0 0 0 300 0 0 0...
Страница 683: ...Appendix 15 MELSEC A APPENDICES Initial value Axis 1 Axis 2 Axis 3 Remarks 0 0 1 0 0 50 80 0 0 980...
Страница 691: ...Appendix 23 MELSEC A APPENDICES Initial value Axis 1 Axis 2 Axis 3 Remarks 0 0 0 0 0 50 80 0 0 0 0 0 980 4000 0...
Страница 745: ......