5 - 64
MELSEC-A
5 DATA USED FOR POSITIONING CONTROL
Servo amplifier
side parameter
Setting value, setting range
Setting value buffer
memory address
Item
No.
Abbre-
viation
Value set with peripheral
device
Value set with sequence
program
Default
value
Axis 1 Axis 2 Axis 3
0 : Servomotor speed
0
H
/
0
H
1 :
Torque
1
H
/
1
H
2 : Servomotor speed (+)
2
H
/
2
H
3 : Torque (+)
3
H
/
3
H
4 : Current command
4
H
/
4
H
5 : Command speed
5
H
/
5
H
6 : Droop pulse 1/1
6
H
/
6
H
7 : Droop pulse 1/4
7
H
/
7
H
8 : Droop pulse 1/16
8
H
/
8
H
9 : Droop pulse 1/32
9
H
/
9
H
Pr.122
Monitor output
mode
selection
No.22 MOD
A : Droop pulse 1/64
A
H
/
A
H
0001
H
122 272 422
Carrier frequency selection
0 : 2.25KHz (Standard)
0
H
3 : 9.0KHz (Low noise)
3
H
Serial encoder cable selection
0 :
2-wire
0
H
Pr.123
Option
function 1
No.23 *OP1
1 : 4-wire (Supports long
distance cables)
1
H
0000
H
123 273 423
Motor-less operation selection
0 :
Invalid
0
H
1 :
Valid
1
H
Solenoid brake interlock output selection
0 : Independent of motor
speed (Output under
specific condition)
0
H
Pr.124
Option
function 2
No.24 *OP2
1 : Output under specific
condition at motor
speed of zero speed or
less
1
H
0000
H
124 274 424
* This parameter is made valid when the servo amplifier is powered OFF, then ON again after it has been transferred
from the AD75 to the servo amplifier.
Pr.122
Monitor output mode selection
Select the signals to be output from the analog monitor CH1 and CH2 of the servo
amplifier.
H
Monitor output 2 selection
Set any of 0 to A. (Refer to the settings of the following monitor output 1)
Monitor output 1 selection
0: Servomotor speed
1: Torque
2: Servomotor speed (+)
3: Torque (+)
4: Current command
5: Command speed
6: Droop pulse 1/1
7: Droop pulse 1/4
8: Droop pulse 1/16
9: Droop pulse 1/32
A: Droop pulse 1/64
0
0
Содержание A1SD75M1
Страница 2: ......
Страница 20: ...A 18 MEMO...
Страница 22: ...MEMO...
Страница 27: ...1 5 MELSEC A 1 PRODUCT OUTLINE MEMO...
Страница 42: ...1 20 MELSEC A 1 PRODUCT OUTLINE MEMO...
Страница 52: ...2 10 MELSEC A 2 SYSTEM CONFIGURATION MEMO...
Страница 111: ...5 21 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 115: ...5 25 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 123: ...5 33 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 127: ...5 37 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 167: ...5 77 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 193: ...5 103 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 276: ...5 186 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 332: ...7 18 MELSEC A 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Страница 334: ...MEMO...
Страница 422: ...9 64 MELSEC A 9 MAIN POSITIONING CONTROL MEMO...
Страница 446: ...10 24 MELSEC A 10 ADVANCED POSITIONING CONTROL MEMO...
Страница 472: ...11 26 MELSEC A 11 MANUAL CONTROL MEMO...
Страница 576: ...12 104 MELSEC A 12 CONTROL AUXILIARY FUNCTIONS MEMO...
Страница 673: ...Appendix 5 MELSEC A APPENDICES Axis address mm inch degree pulse Axis address mm inch degree pulse...
Страница 679: ...Appendix 11 MELSEC A APPENDICES Initial value Axis 1 Axis 2 Axis 3 Remarks 0 0 0 1 1 0 0 0 0 0 300 0 0 0...
Страница 683: ...Appendix 15 MELSEC A APPENDICES Initial value Axis 1 Axis 2 Axis 3 Remarks 0 0 1 0 0 50 80 0 0 980...
Страница 691: ...Appendix 23 MELSEC A APPENDICES Initial value Axis 1 Axis 2 Axis 3 Remarks 0 0 0 0 0 50 80 0 0 0 0 0 980 4000 0...
Страница 745: ......