5 - 117
MELSEC-A
5 DATA USED FOR POSITIONING CONTROL
[Table 1]
When " Pr.1 Unit setting" is "mm"
Da.2
setting value
Value set with peripheral device
(
µ
m)
Value set with sequence program *
1
(
×
10
-1
µ
m)
ABS Linear 1
: 01
H
ABS Linear 2
: 04
H
Current value change
: 11
H
◊
Set the address
–214748364.8 to 214748364.7
◊
Set the address
–2147483648 to 2147483647
INC Linear 1
: 02
H
INC Linear 2
: 05
H
Fixed-dimension feed 1
: 03
H
Fixed dimension feed 2
: 06
H
◊
Set the movement amount
–214748364.8 to 214748364.7
◊
Set the movement amount
–2147483648 to 2147483647
Forward run speed/position : 0F
H
Reverse run speed/position : 10
H
◊
Set the movement amount
0 to 214748364.7
◊
Set the movement amount
0 to 2147483647
Forward run Speed control : 0D
H
Reverse run Speed control : 0E
H
JUMP command
: 20
H
(Setting not required)
(Setting not required)
ABS Circular interpolation : 07
H
ABS Circular right
: 09
H
ABS Circular left
: 0A
H
◊
Set the address
–214748364.8 to 214748364.7
◊
Set the address
–2147483648 to 2147483647
INC Circular interpolation : 08
H
INC Circular right
: 0B
H
INC Circular left
: 0C
H
◊
Set the movement amount
–214748364.8 to 214748364.7
◊
Set the movement amount
–2147483648 to 2147483647
*
1
Decimal points cannot be used in the sequence program, so input the setting value as an integer.
(The value will be converted into the specified value within the system.)
(3) For speed/position changeover control
•
Set the movement amount from when the control changes from the speed
control to the position control.
Speed
Position
control
Movement amount setting
Time
Speed/position changeover
Speed
control
Содержание A1SD75M1
Страница 2: ......
Страница 20: ...A 18 MEMO...
Страница 22: ...MEMO...
Страница 27: ...1 5 MELSEC A 1 PRODUCT OUTLINE MEMO...
Страница 42: ...1 20 MELSEC A 1 PRODUCT OUTLINE MEMO...
Страница 52: ...2 10 MELSEC A 2 SYSTEM CONFIGURATION MEMO...
Страница 111: ...5 21 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 115: ...5 25 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 123: ...5 33 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 127: ...5 37 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 167: ...5 77 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 193: ...5 103 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 276: ...5 186 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 332: ...7 18 MELSEC A 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Страница 334: ...MEMO...
Страница 422: ...9 64 MELSEC A 9 MAIN POSITIONING CONTROL MEMO...
Страница 446: ...10 24 MELSEC A 10 ADVANCED POSITIONING CONTROL MEMO...
Страница 472: ...11 26 MELSEC A 11 MANUAL CONTROL MEMO...
Страница 576: ...12 104 MELSEC A 12 CONTROL AUXILIARY FUNCTIONS MEMO...
Страница 673: ...Appendix 5 MELSEC A APPENDICES Axis address mm inch degree pulse Axis address mm inch degree pulse...
Страница 679: ...Appendix 11 MELSEC A APPENDICES Initial value Axis 1 Axis 2 Axis 3 Remarks 0 0 0 1 1 0 0 0 0 0 300 0 0 0...
Страница 683: ...Appendix 15 MELSEC A APPENDICES Initial value Axis 1 Axis 2 Axis 3 Remarks 0 0 1 0 0 50 80 0 0 980...
Страница 691: ...Appendix 23 MELSEC A APPENDICES Initial value Axis 1 Axis 2 Axis 3 Remarks 0 0 0 0 0 50 80 0 0 0 0 0 980 4000 0...
Страница 745: ......