12 - 59
MELSEC-A
12 CONTROL AUXILIARY FUNCTIONS
(2) Preparations
Note the contents of the following table for preparations of the absolute position
detection system.
Component Description
1) Servo amplifier
(MR-H-B (MR-H-BN),
MR-J-B, MR-J2-B,
MR-J2S-B)
•
Install the battery (MR-BAT, A6BAT) to the servo amplifier.
•
Validate the absolute position detection function of the
servo amplifier.
For other details, refer to the manual of the servo amplifier.
2) Servomotor
•
Use the servomotor with absolute position detector.
For other details, refer to the manual of the servomotor.
3) Detector cable
•
Add the connection of the battery power supply (BAT/LG
signal) to the wiring of the incremental detector cable.
For other details, refer to the manual of the cable.
[2] Outline of absolute position detection data communication
As shown in the system block diagram in Fig. 12.32, the current absolute position is
stored by the battery fitted to the servo amplifier, and the absolute position of the zero
point is stored in the FeRAM of the AD75.
Making a zero point return once at the installation of the machine eliminates the need
for a zero point return at subsequent power-on.
After powering on the AD75 and servo amplifier, start communication between the
AD75 and servo amplifier to restore the absolute position.
AD75
Servo amplifier
Servomotor
Battery
Absolute position data
Unit setting,
No. of pulses per rotation,
Movement amount per
rotation,
Unit magnification,
Rotation direction,
Zero point address
Current feed value
Machine feed value
Absolute position of
zero point
FeRAM
Battery backup
Read
Write
(Detector)
Fig. 12.32 Outline of absolute position restoration function
Содержание A1SD75M1
Страница 2: ......
Страница 20: ...A 18 MEMO...
Страница 22: ...MEMO...
Страница 27: ...1 5 MELSEC A 1 PRODUCT OUTLINE MEMO...
Страница 42: ...1 20 MELSEC A 1 PRODUCT OUTLINE MEMO...
Страница 52: ...2 10 MELSEC A 2 SYSTEM CONFIGURATION MEMO...
Страница 111: ...5 21 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 115: ...5 25 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 123: ...5 33 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 127: ...5 37 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 167: ...5 77 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 193: ...5 103 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 276: ...5 186 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 332: ...7 18 MELSEC A 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Страница 334: ...MEMO...
Страница 422: ...9 64 MELSEC A 9 MAIN POSITIONING CONTROL MEMO...
Страница 446: ...10 24 MELSEC A 10 ADVANCED POSITIONING CONTROL MEMO...
Страница 472: ...11 26 MELSEC A 11 MANUAL CONTROL MEMO...
Страница 576: ...12 104 MELSEC A 12 CONTROL AUXILIARY FUNCTIONS MEMO...
Страница 673: ...Appendix 5 MELSEC A APPENDICES Axis address mm inch degree pulse Axis address mm inch degree pulse...
Страница 679: ...Appendix 11 MELSEC A APPENDICES Initial value Axis 1 Axis 2 Axis 3 Remarks 0 0 0 1 1 0 0 0 0 0 300 0 0 0...
Страница 683: ...Appendix 15 MELSEC A APPENDICES Initial value Axis 1 Axis 2 Axis 3 Remarks 0 0 1 0 0 50 80 0 0 980...
Страница 691: ...Appendix 23 MELSEC A APPENDICES Initial value Axis 1 Axis 2 Axis 3 Remarks 0 0 0 0 0 50 80 0 0 0 0 0 980 4000 0...
Страница 745: ......