5 - 40
MELSEC-A
5 DATA USED FOR POSITIONING CONTROL
Setting value, setting range
Setting value buffer
memory address
Item
Value set with peripheral device
Value set with
sequence program
Default
value
Axis 1 Axis 2 Axis 3
0 : Automatic trapezoid
acceleration/deceleration process
0
Pr.35 Acceleration/decel-
eration process
selection
1 : S-pattern
acceleration/deceleration process
1
0 52
202
352
Pr.36 S-pattern proportion
1 to 100 (%)
1 to 100 (%)
100
53
203
353
Pr.37 Sudden stop
deceleration time
The setting value range differs according to the " Pr.25
Size selection for acceleration/deceleration time" setting.
Here, the value within the [Table 1] range is set.
[Table 1] on right page
1000
54
55
204
205
354
355
Pr.38 Stop group 1 sudden
stop selection
0 : Normal deceleration stop
0
56 206 356
Pr.39 Stop group 2 sudden
stop selection
57 207 357
Pr.40 Stop group 3 sudden
stop selection
1 : Sudden stop
1
0
58 208 358
Pr.35 Acceleration/deceleration process selection
Set whether to use automatic trapezoid acceleration/deceleration or S-pattern
acceleration/deceleration for the acceleration/deceleration process.
Note) Refer to section "12.7.6 Acceleration/deceleration process function" for
details.
Speed
Time
The acceleration and
deceleration are linear.
<Automatic trapezoid acceleration/deceleration>
<S-pattern acceleration/deceleration>
The acceleration and
deceleration follow a Sin curve.
Speed
Time
Содержание A1SD75M1
Страница 2: ......
Страница 20: ...A 18 MEMO...
Страница 22: ...MEMO...
Страница 27: ...1 5 MELSEC A 1 PRODUCT OUTLINE MEMO...
Страница 42: ...1 20 MELSEC A 1 PRODUCT OUTLINE MEMO...
Страница 52: ...2 10 MELSEC A 2 SYSTEM CONFIGURATION MEMO...
Страница 111: ...5 21 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 115: ...5 25 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 123: ...5 33 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 127: ...5 37 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 167: ...5 77 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 193: ...5 103 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 276: ...5 186 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 332: ...7 18 MELSEC A 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Страница 334: ...MEMO...
Страница 422: ...9 64 MELSEC A 9 MAIN POSITIONING CONTROL MEMO...
Страница 446: ...10 24 MELSEC A 10 ADVANCED POSITIONING CONTROL MEMO...
Страница 472: ...11 26 MELSEC A 11 MANUAL CONTROL MEMO...
Страница 576: ...12 104 MELSEC A 12 CONTROL AUXILIARY FUNCTIONS MEMO...
Страница 673: ...Appendix 5 MELSEC A APPENDICES Axis address mm inch degree pulse Axis address mm inch degree pulse...
Страница 679: ...Appendix 11 MELSEC A APPENDICES Initial value Axis 1 Axis 2 Axis 3 Remarks 0 0 0 1 1 0 0 0 0 0 300 0 0 0...
Страница 683: ...Appendix 15 MELSEC A APPENDICES Initial value Axis 1 Axis 2 Axis 3 Remarks 0 0 1 0 0 50 80 0 0 980...
Страница 691: ...Appendix 23 MELSEC A APPENDICES Initial value Axis 1 Axis 2 Axis 3 Remarks 0 0 0 0 0 50 80 0 0 0 0 0 980 4000 0...
Страница 745: ......