5 - 154
MELSEC-A
5 DATA USED FOR POSITIONING CONTROL
Storage item
Storage details
Md.42 Target speed
•
During operation with positioning data
: The actual target speed, considering
the override and speed limit value,
etc., is stored. "0" is stored when
positioning is completed.
•
During interpolation
: The composite speed or reference
axis speed is stored in the reference
axis address, and "0" is stored in the
interpolation axis address.
•
During JOG operation
: The actual target speed, considering
the JOG speed limit value for the
JOG speed, is stored.
•
During manual pulse generator operation : "0" is stored.
Md.43 Zero point absolute position
•
The "zero point absolute position" address is stored.
•
"0" is stored when the power is turned ON, and the zero point return basic
parameter " Pr.47 Zero point address" is stored when the machine zero point
return is completed.
•
The zero point absolute position value is changed when the current value charge
function is executed.
Md.44 Movement amount after
near-point dog ON
•
"0" is stored when machine zero point return starts.
•
After machine zero point return starts, the movement amount from the near-point
dog ON to the machine zero point return completion is stored.
(Movement amount: Movement amount to machine zero point return completion
using near-point dog ON as "0".)
Md.45 Torque limit stored value
The " Pr.18 Torque limit setting value" or " Cd.30 New torque value" is stored.
•
During positioning start, JOG operation start, manual pulse generator operation
...The " Pr.18 Torque limit setting value" is stored.
•
When value is changed to " Cd.30 New torque value" during operation
...The " Cd.30 New torque value" is stored.
Содержание A1SD75M1
Страница 2: ......
Страница 20: ...A 18 MEMO...
Страница 22: ...MEMO...
Страница 27: ...1 5 MELSEC A 1 PRODUCT OUTLINE MEMO...
Страница 42: ...1 20 MELSEC A 1 PRODUCT OUTLINE MEMO...
Страница 52: ...2 10 MELSEC A 2 SYSTEM CONFIGURATION MEMO...
Страница 111: ...5 21 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 115: ...5 25 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 123: ...5 33 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 127: ...5 37 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 167: ...5 77 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 193: ...5 103 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 276: ...5 186 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 332: ...7 18 MELSEC A 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Страница 334: ...MEMO...
Страница 422: ...9 64 MELSEC A 9 MAIN POSITIONING CONTROL MEMO...
Страница 446: ...10 24 MELSEC A 10 ADVANCED POSITIONING CONTROL MEMO...
Страница 472: ...11 26 MELSEC A 11 MANUAL CONTROL MEMO...
Страница 576: ...12 104 MELSEC A 12 CONTROL AUXILIARY FUNCTIONS MEMO...
Страница 673: ...Appendix 5 MELSEC A APPENDICES Axis address mm inch degree pulse Axis address mm inch degree pulse...
Страница 679: ...Appendix 11 MELSEC A APPENDICES Initial value Axis 1 Axis 2 Axis 3 Remarks 0 0 0 1 1 0 0 0 0 0 300 0 0 0...
Страница 683: ...Appendix 15 MELSEC A APPENDICES Initial value Axis 1 Axis 2 Axis 3 Remarks 0 0 1 0 0 50 80 0 0 980...
Страница 691: ...Appendix 23 MELSEC A APPENDICES Initial value Axis 1 Axis 2 Axis 3 Remarks 0 0 0 0 0 50 80 0 0 0 0 0 980 4000 0...
Страница 745: ......