5 - 56
MELSEC-A
5 DATA USED FOR POSITIONING CONTROL
Setting value, setting range
Setting value buffer
memory address
Item
Value set with peripheral
device
Value set with sequence
program
Default
value
Axis 1 Axis 2 Axis 3
Pr.55 Zero point shift
amount
The setting value range differs depending on the " Pr.1
Unit setting".
Here, the value within the [Table 1] range is set.
[Table 1] on right page
0
84
85
234
235
384
385
Pr.56 Zero point return
torque limit value
1 to 300 (%)
1 to 300 (%)
300
86
236
386
0 : Zero point return speed
0
Pr.57 Speed designation
during zero point shift 1 : Creep speed
1
0 88
238
388
Pr.58 Dwell time during
zero point return retry
0 to 65535 (ms)
0 to 65535 (ms)
0 to 32767 :
Set as a decimal
32768 to 65535 :
Convert into hexadecimal
and set
0 89
239
389
0 : Standard mode
0
Pr.59
Absolute position
restoration selection 1 : Infinite length mode
1
0 91
241
391
*: When
Pr.59
is set with the peripheral device, setting can be made using GX Configurator-AP only. For details, refer to
the "GX Configurator-AP Operating Manual".
Pr.55 Zero point shift amount
Set the amount to shift (move) from the position stopped at with machine zero
point return.
* The zero point shift function is used to compensate the zero point position
stopped at with machine zero point return.
If there is a physical limit to the zero point position, due to the relation of the near-
point dog installation position, use this function to compensate the zero point to an
optimum position.
Zero point return direction
When " Zero point
shift amount" is positive
Shift point
Shift point
When " Zero point
shift amount" is negative
Start point
Shift operation is
performed
Near-point dog signal
Zero point
Pr.55
Pr.46
Pr.55
Содержание A1SD75M1
Страница 2: ......
Страница 20: ...A 18 MEMO...
Страница 22: ...MEMO...
Страница 27: ...1 5 MELSEC A 1 PRODUCT OUTLINE MEMO...
Страница 42: ...1 20 MELSEC A 1 PRODUCT OUTLINE MEMO...
Страница 52: ...2 10 MELSEC A 2 SYSTEM CONFIGURATION MEMO...
Страница 111: ...5 21 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 115: ...5 25 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 123: ...5 33 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 127: ...5 37 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 167: ...5 77 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 193: ...5 103 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 276: ...5 186 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 332: ...7 18 MELSEC A 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Страница 334: ...MEMO...
Страница 422: ...9 64 MELSEC A 9 MAIN POSITIONING CONTROL MEMO...
Страница 446: ...10 24 MELSEC A 10 ADVANCED POSITIONING CONTROL MEMO...
Страница 472: ...11 26 MELSEC A 11 MANUAL CONTROL MEMO...
Страница 576: ...12 104 MELSEC A 12 CONTROL AUXILIARY FUNCTIONS MEMO...
Страница 673: ...Appendix 5 MELSEC A APPENDICES Axis address mm inch degree pulse Axis address mm inch degree pulse...
Страница 679: ...Appendix 11 MELSEC A APPENDICES Initial value Axis 1 Axis 2 Axis 3 Remarks 0 0 0 1 1 0 0 0 0 0 300 0 0 0...
Страница 683: ...Appendix 15 MELSEC A APPENDICES Initial value Axis 1 Axis 2 Axis 3 Remarks 0 0 1 0 0 50 80 0 0 980...
Страница 691: ...Appendix 23 MELSEC A APPENDICES Initial value Axis 1 Axis 2 Axis 3 Remarks 0 0 0 0 0 50 80 0 0 0 0 0 980 4000 0...
Страница 745: ......