9 - 18
MELSEC-A
9 MAIN POSITIONING CONTROL
(3) Absolute position detection system
The positioning address is the address of the position reached by the machine
zero point return, and its range is 0° to 359.99999°.
The range 0° to 359.99999° also applies to the case where the zero point
position is not 0°.
<When the mode for absolute position restoration is the "standard
mode" ("
Md.121
Absolute position restoration mode"=0)>
For positioning in the same direction, out of bound control (when the
address increases: 359.99999° to 0°/when the address decreases: 0° to
359.99999°) cannot be performed.
Cannot be used in the absolute
position detection system.
At power-on or reset, the current
value cannot be restored normally.
0
0
359.99999
359.99999
Zero point
Range usable in the absolute position
detection system.
(0 to 359.99999 )
Cannot be used in the absolute
position detection system.
At power-on or reset, the current
value cannot be restored normally.
To make the software stroke limit valid, set the upper and lower limit values
within the range 0° to 359.99999°.
<When the mode for absolute position restoration is the "infinite
length mode" ("
Md.121
Absolute position restoration mode"=1)>
For positioning in the same direction, out of bound control (when the
address increases: 359.99999° to 0°/when the address decreases: 0° to
359.99999°) can be performed.
0
0
359.99999
359.99999
Zero point
Out of bound positioning control can
be performed.
(Infinite length positioning control)
Make the software stroke limit invalid.
For details of the mode for absolute position restoration, refer to section "12.6.2
Absolute position restoration mode switching function".
Содержание A1SD75M1
Страница 2: ......
Страница 20: ...A 18 MEMO...
Страница 22: ...MEMO...
Страница 27: ...1 5 MELSEC A 1 PRODUCT OUTLINE MEMO...
Страница 42: ...1 20 MELSEC A 1 PRODUCT OUTLINE MEMO...
Страница 52: ...2 10 MELSEC A 2 SYSTEM CONFIGURATION MEMO...
Страница 111: ...5 21 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 115: ...5 25 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 123: ...5 33 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 127: ...5 37 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 167: ...5 77 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 193: ...5 103 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 276: ...5 186 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Страница 332: ...7 18 MELSEC A 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Страница 334: ...MEMO...
Страница 422: ...9 64 MELSEC A 9 MAIN POSITIONING CONTROL MEMO...
Страница 446: ...10 24 MELSEC A 10 ADVANCED POSITIONING CONTROL MEMO...
Страница 472: ...11 26 MELSEC A 11 MANUAL CONTROL MEMO...
Страница 576: ...12 104 MELSEC A 12 CONTROL AUXILIARY FUNCTIONS MEMO...
Страница 673: ...Appendix 5 MELSEC A APPENDICES Axis address mm inch degree pulse Axis address mm inch degree pulse...
Страница 679: ...Appendix 11 MELSEC A APPENDICES Initial value Axis 1 Axis 2 Axis 3 Remarks 0 0 0 1 1 0 0 0 0 0 300 0 0 0...
Страница 683: ...Appendix 15 MELSEC A APPENDICES Initial value Axis 1 Axis 2 Axis 3 Remarks 0 0 1 0 0 50 80 0 0 980...
Страница 691: ...Appendix 23 MELSEC A APPENDICES Initial value Axis 1 Axis 2 Axis 3 Remarks 0 0 0 0 0 50 80 0 0 0 0 0 980 4000 0...
Страница 745: ......