v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 3, “Parts listing, Types 7901 and 7902,” on page 19 to determine which components are CRUs and
which components are FRUs.
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Beep code
Description
Action
1-1-4
BIOS ROM checksum failed.
1.
Update the BIOS code (see “Firmware
updates” on page 17).
2.
Reseat the DIMMs (see “Removing a
memory module” on page 37 and
“Installing a memory module” on page 38).
3.
Replace the following components one at a
time, in the order shown, restarting the
blade server each time:
a.
DIMMs (see “Removing a memory
module” on page 37 and “Installing a
memory module” on page 38)
b.
(Trained service technician only)
system-board assembly (see “Removing
the system-board assembly” on page 62
and “Installing the system-board
assembly” on page 62)
1-2-1
Programmable interval timer failed.
(Trained service technician only) Replace the
system-board assembly (see “Removing the
system-board assembly” on page 62 and
“Installing the system-board assembly” on
page 62).
1-2-2
DMA initialization failed.
(Trained service technician only) Replace the
system-board assembly (see “Removing the
system-board assembly” on page 62 and
“Installing the system-board assembly” on
page 62).
1-2-3
DMA page register write/read failed.
(Trained service technician only) Replace the
system-board assembly (see “Removing the
system-board assembly” on page 62 and
“Installing the system-board assembly” on
page 62).
Chapter 5. Diagnostics
67
Содержание LS42 - BladeCenter - 7902
Страница 1: ...BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Страница 12: ...x BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Страница 76: ...64 BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Страница 192: ...180 BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Страница 193: ......
Страница 194: ...Part Number 49Y0107 Printed in USA 1P P N 49Y0107...