Table 5. Additional diagnostic error codes (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Table 1 on page 21 to determine which components are customer replaceable units (CRU) and which
components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
030-xxx-000
Failed internal SAS interface test
(Trained service technician only) Replace the
system-board assembly (see “Removing the system-board
assembly” on page 62 and “Installing the system-board
assembly” on page 62).
035-xxx-099
No adapters were found
If a PCI-X or PCIe adapter is installed in the blade server
or the MPE unit, reseat the adapter (see “Removing an
I/O expansion card” on page 39 and “Installing an I/O
expansion card” on page 43).
075-xxx-000
Failed power supply test
Replace the power supply (see the
Hardware Maintenance
Manual and Troubleshooting Guide
or the
Problem
Determination and Service Guide
for your BladeCenter
unit).
150
BladeCenter LS22 Type 7901 and LS42 Type 7902: Problem Determination and Service Guide
Содержание LS42 - BladeCenter - 7902
Страница 1: ...BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Страница 12: ...x BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Страница 76: ...64 BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Страница 192: ...180 BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Страница 193: ......
Страница 194: ...Part Number 49Y0107 Printed in USA 1P P N 49Y0107...