Table 4. Diagnostic error codes (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 3, “Parts listing, Types 7901 and 7902,” on page 19 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Message
number
Component
Test
State
Description
Action
202-802-xxx
Memory
Memory
Stress Test
Abort
Test aborted.
Memory size is
insufficient to
run the test. At
least 1 GB of
memory is
required to run
the test.
1.
Turn off and restart the system.
2.
Run the test again.
3.
Make sure that the DSA code is at the
latest level. For the latest level of DSA
code, go to http://www.ibm.com/
support/docview.wss?uid=psg1SERV-
DSA.
4.
Run the test again.
5.
Run the standard memory test to
validate all memory.
6.
See “Solving undetermined problems”
on page 164.
202-901-xxx
Memory
Memory
Stress Test
Failed
Test failure.
1.
Run the standard memory test to
validate all memory.
2.
Make sure that the DSA code is at the
latest level. For the latest level of DSA
code, go to http://www.ibm.com/
support/docview.wss?uid=psg1SERV-
DSA.
3.
Reseat the DIMMs (see “Removing a
memory module” on page 37 and
“Installing a memory module” on page
38).
4.
Run the test again.
5.
Run the standard DSA memory
diagnostic to validate all memory.
6.
See “Solving undetermined problems”
on page 164.
215–000–xxx
Optical drive Self-test
Pass
The optical drive passed the test. No
action is required.
Chapter 5. Diagnostics
137
Содержание LS42 - BladeCenter - 7902
Страница 1: ...BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Страница 12: ...x BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Страница 76: ...64 BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Страница 192: ...180 BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Страница 193: ......
Страница 194: ...Part Number 49Y0107 Printed in USA 1P P N 49Y0107...