Select this choice to view or change the start options. Changes in the start
options take effect when you start the blade server.
–
Startup Sequence Options
Select this choice to view or change the startup device sequence that is set for
the blade server.
You can set keyboard operating characteristics, such as whether the blade server
starts with the keyboard number lock on or off. You can enable the blade server
to run without a diskette drive or keyboard.
You can enable or disable the PXE option for either of the integrated Gigabit
Ethernet controllers. If the MPE unit is installed, you can enable or disable the
PXE option for either of its integrated Gigabit Ethernet controllers. The default
setting for
Planar Ethernet 1
and
Planar Ethernet 2
is enabled, and if the MPE is
installed, the default setting for
Planar Ethernet 3
and
Planar Ethernet 4
is
disabled.
You can enable USB disk support, which enables the blade server to use a USB
storage device that is connected to the USB port in the media tray of the
BladeCenter unit. See the documentation for your BladeCenter unit for
additional information.
If you enable the boot fail count, the BIOS default settings will be restored after
three consecutive failures to find a boot record.
You can enable a virus-detection test that checks for changes in the boot record
when the blade server starts.
v
Advanced Setup
Select this choice to change settings for advanced hardware features.
Important:
The blade server might malfunction if these settings are incorrectly
configured. Follow the instructions on the screen carefully.
–
Memory Settings
Select this choice to manually enable a pair of memory connectors.
If a memory error is detected during POST or memory configuration, the
blade server automatically disables the failing memory pair of memory
connectors and continues operating with reduced memory. After the problem
is corrected, you must enable the memory connectors. Use the arrow keys to
highlight the pair of memory connectors that you want to enable, and use the
arrow keys to select
Enable
.
–
PCI Bus Control
Select this choice to view and set interrupts for PCI devices, enable or disable
PCI ROM control, and to configure the master-latency-timer value for the
blade server.
–
Baseboard Management Controller (BMC) Settings
Select this choice to enable or disable the
Reboot on System NMI
option on
the menu. If you enable this option, the blade server will automatically restart
60 seconds after the service processor issues a nonmaskable interrupt (NMI)
to the blade server. You can also select this choice to enable or disable and set
the timeouts for the POST and OS loader watchdog timers.
–
BMC Network Configuration
Select this choice to set the network addresses of the BMC.
–
BMC System Event Log
Select this choice to view and clear BMC event log entries.
v
Save Settings
Select this choice to save the changes that you have made in the settings.
Chapter 2. Configuring the blade server
13
Содержание LS42 - BladeCenter - 7902
Страница 1: ...BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Страница 12: ...x BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Страница 76: ...64 BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Страница 192: ...180 BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Страница 193: ......
Страница 194: ...Part Number 49Y0107 Printed in USA 1P P N 49Y0107...