Table 4. Diagnostic error codes (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 3, “Parts listing, Types 7901 and 7902,” on page 19 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Message
number
Component
Test
State
Description
Action
201–877–xxx
Memory
Memory
Test
Abort
Test aborted:
Sparing must
be turned off in
extended PCI
space.
1.
Turn off and restart the system.
2.
Run the Configuration/Setup Utility
program (see “Using the Setup Utility
program” on page 11).
3.
Disable memory sparing.
4.
Make sure that the system BIOS code
is at the latest level. The installed
firmware level is shown in the DSA
event log in the Firmware/VPD section
for this component. For the latest level
of firmware, go to
http://www.ibm.com/support/
docview.wss?uid=psg1 MIGR-4JTS2T
and select your system to display a
matrix of available firmware.
5.
Run the test again.
6.
See “Solving undetermined problems”
on page 164.
201–878–xxx
Memory
Memory
Test
Abort
Test aborted:
Sparing is
enabled in PCI
space.
1.
Turn off and restart the system.
2.
Run the Configuration/Setup Utility
program (see “Using the Setup Utility
program” on page 11).
3.
Disable memory sparing.
4.
Make sure that the system BIOS code
is at the latest level. The installed
firmware level is shown in the DSA
event log in the Firmware/VPD section
for this component. For the latest level
of firmware, go to
http://www.ibm.com/support/
docview.wss?uid=psg1 MIGR-4JTS2T
and select your system to display a
matrix of available firmware.
5.
Run the test again.
6.
See “Solving undetermined problems”
on page 164.
Chapter 5. Diagnostics
133
Содержание LS42 - BladeCenter - 7902
Страница 1: ...BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Страница 12: ...x BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Страница 76: ...64 BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Страница 192: ...180 BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Страница 193: ......
Страница 194: ...Part Number 49Y0107 Printed in USA 1P P N 49Y0107...