Table 5. Additional diagnostic error codes (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Table 1 on page 21 to determine which components are customer replaceable units (CRU) and which
components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
202-xxx-00n
Failed system cache test.
1.
(Trained service technician only) Reseat
microprocessor
n
(see “Removing a microprocessor
and heat sink” on page 57 and “Installing a
microprocessor and heat sink” on page 59).
2.
Replace the following components one at a time, in
the order shown, restarting the blade server each
time:
a.
(Trained service technician only) Microprocessor n
(see “Removing a microprocessor and heat sink”
on page 57 and “Installing a microprocessor and
heat sink” on page 59).
b.
(Trained service technician only) MPE board
assembly, if microprocessor n is on the MPE (see
“Removing an expansion unit” on page 31 and
“Installing an expansion unit” on page 32).
c.
(Trained service technician only) System board, if
microprocessor
n
is on the blade server (see
“Removing the system-board assembly” on page
62 and “Installing the system-board assembly” on
page 62).
217-198-xxx
Could not establish drive parameters.
1.
Reseat hard disk drive
x
(see “Removing a SAS
drive” on page 35 and “Installing a SAS drive” on
page 36).
2.
Update the BIOS code (see “Firmware updates” on
page 17).
3.
Replace the following components one at a time, in
the order shown, restarting the blade server each
time:
a.
Hard disk drive
x
(see “Removing a SAS drive”
on page 35 and “Installing a SAS drive” on page
36).
b.
(Trained service technician only) System-board
assembly (see “Removing the system-board
assembly” on page 62 and “Installing the
system-board assembly” on page 62).
217-xxx-000
Failed hard disk drive test.
Note:
If RAID is configured, the SAS
Attached Disk number refers to the
RAID logical drive.
1.
Reseat hard disk drive 1 (see “Removing a SAS
drive” on page 35 and “Installing a SAS drive” on
page 36).
2.
Replace hard disk drive 1 (see “Removing a SAS
drive” on page 35 and “Installing a SAS drive” on
page 36).
Chapter 5. Diagnostics
157
Содержание LS42 - BladeCenter - 7902
Страница 1: ...BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Страница 12: ...x BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Страница 76: ...64 BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Страница 192: ...180 BladeCenter LS22 Type 7901 and LS42 Type 7902 Problem Determination and Service Guide...
Страница 193: ......
Страница 194: ...Part Number 49Y0107 Printed in USA 1P P N 49Y0107...