Table 38. DSA messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only)”, that step must be performed only by a trained
technician.
v
Go to the IBM support website at http://www.ibm.com/supportportal to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Message
number
Component Test
State
Description
Action
201-901-xxx
Memory
Memory Test Failed
Test failure:
single-bit error,
failing DIMM z.
1.
Turn off the system and disconnect
it from the power source.
2.
Reseat DIMM z.
3.
Reconnect the system to power and
turn on the system.
4.
Make sure that the DSA code is at
the latest level.
5.
Make sure that the server firmware
is at the latest level. The installed
firmware level is shown in the DSA
event log in the Firmware/VPD
section for this component.
6.
Run the test again.
7.
Replace the failing DIMMs.
8.
Re-enable all memory in the Setup
utility.
9.
Run the test again.
10.
Replace the failing DIMM.
11.
Re-enable all memory in the Setup
utility.
12.
Run the test again.
13.
If the failure remains, go to the IBM
website for more troubleshooting
information.
202-801-xxx
Memory
Memory
Stress Test
Aborted
Internal program
error.
1.
Turn off and restart the system.
2.
Make sure that the DSA code is at
the latest level.
3.
Make sure that the server firmware is
at the latest level. The installed
firmware level is shown in the DSA
event log in the Firmware/VPD
section for this component.
4.
Run the test again.
5.
Turn off and restart the system if
necessary to recover from a hung
state.
6.
Run the memory diagnostics to
identify the specific failing DIMM.
7.
If the failure remains, go to the IBM
website for more troubleshooting
information.
386
System x3500 M4 Type 7383: Installation and Service Guide
Содержание 7383
Страница 1: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 8: ...vi System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 42: ...24 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 65: ...Figure 19 Server with sixteen 2 5 inch hard disk drives Chapter 2 Installing optional devices 47 ...
Страница 200: ...182 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 235: ...Figure 53 Server with eight 2 5 inch hard disk drives Chapter 6 Removing and replacing components 217 ...
Страница 236: ...Figure 54 Server with sixteen 2 5 inch hard disk drives 218 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 237: ...Figure 55 Server with twenty four 2 5 inch hard disk drives Chapter 6 Removing and replacing components 219 ...
Страница 360: ...342 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 416: ...398 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 470: ...452 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 479: ...Taiwan Class A compliance statement Notices 461 ...
Страница 480: ...462 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 487: ......
Страница 488: ... Part Number 46W8192 Printed in USA 1P P N 46W8192 ...