Table 39. IMM error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only)”, that step must be performed only by a trained
technician.
800b050a-1e81ffff
Fan Zone insufficient
resources has
asserted.
Error
There is no
redundancy and
insufficient to
continue operation.
1.
Make sure that the connectors on
fans are not damaged and all fans
are installed correctly.
2.
Check Fan
n
Tach error logs to
determine fan
n
.
3.
Make sure that the fan
n
connector
on the system board is not
damaged.
4.
Make sure that fan
n
is correctly
installed.
5.
Reseat fan
n
.
6.
Replace fan
n
(see Removing a
simple-swap fan and Installing a
simple-swap fan).
(
n
= fan number)
80070204-0a01ffff
80070204-0a02ffff
Sensor PS
n
Fan
Fault has transitioned
to critical from a less
severe state. (
n
=
power supply
number)
Error
A sensor has
changed to Critical
state from a less
severe state.
1.
Make sure that there are no
obstructions, such as bundled
cables, to the airflow from the
power-supply fan.
2.
Replace power supply
n
(see
Remove a hot-swap power supply
and Installing a hot-swap power
supply).
(
n
= power supply number)
Power messages
80010902-0701ffff
Numeric sensor
SysBrd 3.3V going
high (upper critical)
has asserted.
Error
An upper critical
sensor going high
has asserted.
(Trained technician only) Replace the
system board (see Removing the
system board and Installing the system
board).
80010202-0701ffff
Numeric sensor
SysBrd 3.3V going
low (lower critical)
has asserted.
Error
A lower critical
sensor going low
has asserted.
(Trained technician only) Replace the
system board (see Removing the
system board and Installing the system
board).
80010902-0701ffff
Numeric sensor
SysBrd 5V going
high (upper critical)
has asserted.
Error
An upper critical
sensor going high
has asserted.
1.
Replace the power paddle card (see
Removing the power paddle card
and Installing the power paddle
card).
2.
(Trained technician only) Replace
the system board (see Removing the
system board and Installing the
system board).
Appendix C. Integrated management module II (IMM2) error messages
403
Содержание 7383
Страница 1: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 8: ...vi System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 42: ...24 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 65: ...Figure 19 Server with sixteen 2 5 inch hard disk drives Chapter 2 Installing optional devices 47 ...
Страница 200: ...182 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 235: ...Figure 53 Server with eight 2 5 inch hard disk drives Chapter 6 Removing and replacing components 217 ...
Страница 236: ...Figure 54 Server with sixteen 2 5 inch hard disk drives 218 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 237: ...Figure 55 Server with twenty four 2 5 inch hard disk drives Chapter 6 Removing and replacing components 219 ...
Страница 360: ...342 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 416: ...398 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 470: ...452 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 479: ...Taiwan Class A compliance statement Notices 461 ...
Страница 480: ...462 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 487: ......
Страница 488: ... Part Number 46W8192 Printed in USA 1P P N 46W8192 ...