Table 39. IMM error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only)”, that step must be performed only by a trained
technician.
806f0a0c-2001ffff
806f0a0c-2002ffff
806f0a0c-2003ffff
806f0a0c-2004ffff
806f0a0c-2005ffff
806f0a0c-2006ffff
806f0a0c-2007ffff
806f0a0c-2008ffff
806f0a0c-2009ffff
806f0a0c-200affff
806f0a0c-200bffff
806f0a0c-200cffff
806f0a0c-200dffff
806f0a0c-200effff
806f0a0c-200fffff
806f0a0c-2010ffff
806f0a0c-2011ffff
806f0a0c-2012ffff
806f0a0c-2013ffff
806f0a0c-2014ffff
806f0a0c-2015ffff
806f0a0c-2016ffff
806f0a0c-2017ffff
806f0a0c-2018ffff
An
Over-Temperature
condition has been
detected on the
DIMM
n
Status. (
n
=
DIMM number)
Error
An
over-temperature
condition has
occurred for DIMM
n
. (
n
= DIMM
number)
1.
Make sure that the fans are
operating, that there are no
obstructions to the airflow, that the
air baffles are in place and correctly
installed, and that the server cover
is installed and completely closed.
2.
Make sure that ambient
temperature is within the
specifications.
3.
If a fan has failed, complete the
action for a fan failure.
4.
Replace DIMM
n
.
(
n
= DIMM number)
800b010c-2581ffff
Backup Memory
redundancy lost has
asserted.
Error
Redundancy has
been lost.
1.
Check the system-event log for
DIMM failure events (uncorrectable
or PFA) and correct the failures.
2.
Re-enable mirrored mode in the
Setup utility.
800b030c-2581ffff
Backup Memory
sufficient resources
from redundancy
degraded has
asserted.
Warning There is no
redundancy. The
state has been
transitioned from
redundancy to
sufficient resources.
1.
Check the system-event log for
DIMM failure events (uncorrectable
or PFA) and correct the failures.
2.
Re-enable mirrored mode in the
Setup utility.
800b050c-2581ffff
Backup Memory
insufficient resources
has asserted.
Error
There is no
redundancy and
insufficient to
continue operation.
1.
Check the system-event log for
DIMM failure events (uncorrectable
or PFA) and correct the failures.
2.
Re-enable mirrored mode in the
Setup utility.
Storage messages
Appendix C. Integrated management module II (IMM2) error messages
425
Содержание 7383
Страница 1: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 8: ...vi System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 42: ...24 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 65: ...Figure 19 Server with sixteen 2 5 inch hard disk drives Chapter 2 Installing optional devices 47 ...
Страница 200: ...182 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 235: ...Figure 53 Server with eight 2 5 inch hard disk drives Chapter 6 Removing and replacing components 217 ...
Страница 236: ...Figure 54 Server with sixteen 2 5 inch hard disk drives 218 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 237: ...Figure 55 Server with twenty four 2 5 inch hard disk drives Chapter 6 Removing and replacing components 219 ...
Страница 360: ...342 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 416: ...398 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 470: ...452 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 479: ...Taiwan Class A compliance statement Notices 461 ...
Страница 480: ...462 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 487: ......
Страница 488: ... Part Number 46W8192 Printed in USA 1P P N 46W8192 ...