Table 37. UEFI/POST diagnostic codes (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only)”, that step must be performed only by a trained
technician.
v
Go to the IBM support website at http://www.ibm.com/supportportal to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Diagnostic
code
Message
Description
Action
I.3818002
[I.3818002] The
firmware image
capsule signature
for the non-booted
flash bank is
invalid.
Opposite Bank
CRTM Capsule
Update
Signature
Invalid.
1.
Run the Setup utility, select
Load Default Settings
, and
save the settings.
2.
Recover the server firmware (see Recovering the server
firmware).
3.
If error does not persist, no additional recovery action is
required.
4.
If error persists, or boot is unsuccessful, (trained technician
only) replace the system board (see Removing the system
board and Installing the system board).
I.3818003
[I.3818003] The
CRTM flash driver
could not lock the
secure flash region.
CRTM Could
not lock secure
flash region.
1.
Continue booting system. If system does not reset,
manually reset the system.
2.
If the error is not reported on the subsequent boot, no
additional recovery action is required.
3.
If the error persists, continue booting system and refresh
UEFI image.
4.
(Trained technician only) Replace the system board (see
Removing the system board and Installing the system
board).
S.3818004
[S.3818004] The
CRTM flash driver
could not
successfully flash
the staging area. A
failure occurred.
CRTM Update
Failed.
1.
Continue booting system. If system does not reset,
manually reset the system.
2.
If the error is not reported on the subsequent boot, no
additional recovery action is required.
3.
If the error persists, continue booting system and refresh
UEFI image.
4.
(Trained technician only) Replace the system board (see
Removing the system board and Installing the system
board).
W.3818005
[W.3818005] The
CRTM flash driver
could not
successfully flash
the staging area.
The update was
aborted.
CRTM Update
Aborted.
1.
Continue booting system. If system does not reset,
manually reset the system.
2.
If the error is not reported on the subsequent boot, no
additional recovery action is required.
3.
If the error persists, continue booting system and refresh
UEFI image.
4.
(Trained technician only) Replace the system board (see
Removing the system board and Installing the system
board).
Appendix A. UEFI/POST error codes
359
Содержание 7383
Страница 1: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 8: ...vi System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 42: ...24 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 65: ...Figure 19 Server with sixteen 2 5 inch hard disk drives Chapter 2 Installing optional devices 47 ...
Страница 200: ...182 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 235: ...Figure 53 Server with eight 2 5 inch hard disk drives Chapter 6 Removing and replacing components 217 ...
Страница 236: ...Figure 54 Server with sixteen 2 5 inch hard disk drives 218 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 237: ...Figure 55 Server with twenty four 2 5 inch hard disk drives Chapter 6 Removing and replacing components 219 ...
Страница 360: ...342 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 416: ...398 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 470: ...452 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 479: ...Taiwan Class A compliance statement Notices 461 ...
Страница 480: ...462 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 487: ......
Страница 488: ... Part Number 46W8192 Printed in USA 1P P N 46W8192 ...