Table 37. UEFI/POST diagnostic codes (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only)”, that step must be performed only by a trained
technician.
v
Go to the IBM support website at http://www.ibm.com/supportportal to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Diagnostic
code
Message
Description
Action
I.1800C
[I.1800C] A cache
type mismatch has
been detected for
one or more
processor packages.
Processors have
one or more
cache levels
with
mismatched
type.
1.
Make sure that the microprocessor is on the ServerProven
website at http://www.ibm.com/systems/info/x86servers/
serverproven/compat/us.
2.
Verify that matching processors are installed in the correct
processor sockets for the server. Correct any mismatch
issues found.
3.
Check the IBM support website for a firmware update and
update the server firmware to the latest level (see Updating
the firmware).
4.
(Trained technician only) Remove and replace the affected
microprocessor (error LED is lit) with a supported type (see
Removing a microprocessor and heat sink and Installing a
microprocessor and heat sink).
I.1800D
[I.1800D] A cache
associativity
mismatch has been
detected for one or
more processor
packages.
Processors have
one or more
cache levels
with
mismatched
associativity.
1.
Make sure that the microprocessor is on the ServerProven
website at http://www.ibm.com/systems/info/x86servers/
serverproven/compat/us.
2.
Verify that matching processors are installed in the correct
processor sockets for the server. Correct any mismatch
issues found.
3.
Check the IBM support website for a firmware update and
update the server firmware to the latest level (see Updating
the firmware).
4.
(Trained technician only) Remove and replace the affected
microprocessor (error LED is lit) with a supported type (see
Removing a microprocessor and heat sink and Installing a
microprocessor and heat sink).
I.1800E
[I.1800E] A
processor model
mismatch has been
detected for one or
more processor
packages.
Processors have
mismatched
Model Number.
1.
Make sure that the microprocessor is on the ServerProven
website at http://www.ibm.com/systems/info/x86servers/
serverproven/compat/us.
2.
Verify that matching processors are installed in the correct
processor sockets for the server. Correct any mismatch
issues found.
3.
Check the IBM support website for a firmware update and
update the server firmware to the latest level (see Updating
the firmware).
4.
(Trained technician only) Remove and replace the affected
microprocessor (error LED is lit) with a supported type (see
Removing a microprocessor and heat sink and Installing a
microprocessor and heat sink).
346
System x3500 M4 Type 7383: Installation and Service Guide
Содержание 7383
Страница 1: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 8: ...vi System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 42: ...24 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 65: ...Figure 19 Server with sixteen 2 5 inch hard disk drives Chapter 2 Installing optional devices 47 ...
Страница 200: ...182 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 235: ...Figure 53 Server with eight 2 5 inch hard disk drives Chapter 6 Removing and replacing components 217 ...
Страница 236: ...Figure 54 Server with sixteen 2 5 inch hard disk drives 218 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 237: ...Figure 55 Server with twenty four 2 5 inch hard disk drives Chapter 6 Removing and replacing components 219 ...
Страница 360: ...342 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 416: ...398 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 470: ...452 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 479: ...Taiwan Class A compliance statement Notices 461 ...
Страница 480: ...462 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 487: ......
Страница 488: ... Part Number 46W8192 Printed in USA 1P P N 46W8192 ...