Table 39. IMM error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only)”, that step must be performed only by a trained
technician.
80010b01-2d01ffff
Numeric sensor PCH
Temp going high
(upper
non-recoverable) has
asserted.
Error
An upper
non-recoverable
sensor going high
has asserted.
Check the server airflow. Make sure
that nothing is blocking the air from
coming into or preventing the air from
exiting the server.
81010701-2d01ffff
Numeric sensor PCH
Temp going high
(upper non-critical)
has deasserted.
Info
An upper
non-critical sensor
going high has
deasserted.
No action; information only.
81010901-2d01ffff
Numeric sensor PCH
Temp going high
(upper critical) has
deasserted.
Info
An upper critical
sensor going high
has deasserted.
No action; information only.
81010b01-2d01ffff
Numeric sensor PCH
Temp going high
(upper
non-recoverable) has
deasserted.
Info
An upper
non-recoverable
sensor going high
has deasserted.
No action; information only.
80010204-1d01ffff
80010204-1d02ffff
80010204-1d03ffff
80010204-1d04ffff
80010204-1d05ffff
80010204-1d06ffff
Numeric sensor Fan
n
Tach going low
(lower critical) has
asserted. (
n
= fan
number)
Error
A lower critical
sensor going low
has asserted.
1.
Reseat the failing fan
n
.
2.
Replace the failing fan (see
Removing a simple-swap fan and
Installing a simple-swap fan).
(
n
= fan number)
800b010a-1e81ffff
Fan Zone
redundancy lost has
asserted.
Error
Redundancy lost
has asserted.
1.
Make sure that the connectors on
fans are not damaged and all fans
are installed correctly.
2.
Check Fan
n
Tach error logs to
determine fan
n
.
3.
Make sure that the fan
n
connector
on the system board is not
damaged.
4.
Make sure that fan
n
is correctly
installed.
5.
Reseat fan
n
.
6.
Replace fan
n
(see Removing a
simple-swap fan and Installing a
simple-swap fan).
(
n
= fan number)
402
System x3500 M4 Type 7383: Installation and Service Guide
Содержание 7383
Страница 1: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 8: ...vi System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 42: ...24 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 65: ...Figure 19 Server with sixteen 2 5 inch hard disk drives Chapter 2 Installing optional devices 47 ...
Страница 200: ...182 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 235: ...Figure 53 Server with eight 2 5 inch hard disk drives Chapter 6 Removing and replacing components 217 ...
Страница 236: ...Figure 54 Server with sixteen 2 5 inch hard disk drives 218 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 237: ...Figure 55 Server with twenty four 2 5 inch hard disk drives Chapter 6 Removing and replacing components 219 ...
Страница 360: ...342 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 416: ...398 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 470: ...452 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 479: ...Taiwan Class A compliance statement Notices 461 ...
Страница 480: ...462 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 487: ......
Страница 488: ... Part Number 46W8192 Printed in USA 1P P N 46W8192 ...