v
For information about power-supply problems, see “Solving power problems”
on page 166, “Power problems” on page 162, and “Power-supply LEDs” on page
142.
v
For intermittent problems, check the event log; see “Event logs” on page 144 and
Appendix B, “DSA messages,” on page 361.
Performing the checkout procedure
Use this information to perform the checkout procedure.
About this task
To perform the checkout procedure, complete the following steps:
Procedure
1.
Is the server part of a cluster?
v
No:
Go to step 2.
v
Yes:
Shut down all failing servers that are related to the cluster. Go to step 2.
2.
Complete the following steps:
a.
Check the power supply LEDs (see “Power-supply LEDs” on page 142).
b.
Turn off the server and all external devices.
c.
Check all internal and external devices for compatibility at
http://www.ibm.com/systems/info/x86servers/serverproven/compat/us.
d.
Check all cables and power cords.
e.
Set all display controls to the middle positions.
f.
Turn on all external devices.
g.
Turn on the server. If the server does not start, see “Troubleshooting by
symptom” on page 151.
h.
Check the system-error LED on the operator information panel. If it is lit,
check the light path diagnostics LEDs (see “Light path diagnostics” on page
136).
i.
Check for the following results:
v
Successful completion of POST (see “UEFI/POST” on page 147 for more
information).
v
Successful completion of startup, which is indicated by a readable display
of the operating-system desktop.
3.
Is there a readable image on the monitor screen?
v
No:
Find the failure symptom in “Troubleshooting by symptom” on page
151; if necessary, see “Solving undetermined problems” on page 168.
v
Yes:
Run DSA (see “Running DSA Preboot diagnostic programs” on page
149).
– If DSA reports an error, follow the instructions in Appendix B, “DSA
– If DSA does not report an error but you still suspect a problem, see
“Solving undetermined problems” on page 168.
Chapter 4. Troubleshooting
133
Содержание 7383
Страница 1: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 8: ...vi System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 42: ...24 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 65: ...Figure 19 Server with sixteen 2 5 inch hard disk drives Chapter 2 Installing optional devices 47 ...
Страница 200: ...182 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 235: ...Figure 53 Server with eight 2 5 inch hard disk drives Chapter 6 Removing and replacing components 217 ...
Страница 236: ...Figure 54 Server with sixteen 2 5 inch hard disk drives 218 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 237: ...Figure 55 Server with twenty four 2 5 inch hard disk drives Chapter 6 Removing and replacing components 219 ...
Страница 360: ...342 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 416: ...398 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 470: ...452 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 479: ...Taiwan Class A compliance statement Notices 461 ...
Страница 480: ...462 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 487: ......
Страница 488: ... Part Number 46W8192 Printed in USA 1P P N 46W8192 ...