Table 37. UEFI/POST diagnostic codes (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only)”, that step must be performed only by a trained
technician.
v
Go to the IBM support website at http://www.ibm.com/supportportal to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Diagnostic
code
Message
Description
Action
W.58007
[W.58007] Invalid
memory
configuration
(Unsupported
DIMM Population)
detected. Please
verify memory
configuration is
valid.
Unsupported
DIMM
Population.
Note:
Each time you install or remove a DIMM, you must
disconnect the server from the power source; then, wait 10
seconds before restarting the server.
1.
Reseat the DIMMs and restart the server (see Removing a
memory module and Memory module installation).
2.
Make sure that the DIMMs are installed in the proper
sequence (see Memory module installation).
S.58008
[S.58008] A DIMM
has failed the POST
memory test.
DIMM Failed
Memory Test.
Note:
Each time you install or remove a DIMM, you must
disconnect the server from the power source; then, wait 10
seconds before restarting the server.
1.
Check the IBM support website for an applicable retain tip
or firmware update that applies to this memory error.
2.
Make sure that the DIMMs are firmly seated and no
foreign material is found in the DIMM connector. Then,
retry with the same DIMM.
3.
If the problem is related to a DIMM, replace the failing
DIMM indicated by the error LEDs (see Removing a
memory module and Memory module installation).
4.
If the problem occurs on the same DIMM connector, swap
the affected DIMMs (as indicated by the error LEDs on the
system board or the event logs) to a different memory
channel or microprocessor (see Memory module
installation).
5.
(Trained technician only) If the problem occurs on the same
DIMM connector, check the DIMM connector. If the
connector contains any foreign material or is damaged,
replace the system board (see Removing the system board
and Installing the system board).
6.
(Trained technician only) Remove the affected
microprocessor and check the microprocessor socket pins
for any damaged pins. If a damage is found, replace the
system board (see Removing the system board and
Installing the system board).
7.
(Trained technician only) Swap the affected microprocessor,
if there are more than one microprocessor installed. If the
problem follows the microprocessor, replace the affected
microprocessor (see Removing a microprocessor and heat
sink and Installing a microprocessor and heat sink).
8.
(Trained technician only) Replace the system board (see
Removing the system board and Installing the system
board).
350
System x3500 M4 Type 7383: Installation and Service Guide
Содержание 7383
Страница 1: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 8: ...vi System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 42: ...24 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 65: ...Figure 19 Server with sixteen 2 5 inch hard disk drives Chapter 2 Installing optional devices 47 ...
Страница 200: ...182 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 235: ...Figure 53 Server with eight 2 5 inch hard disk drives Chapter 6 Removing and replacing components 217 ...
Страница 236: ...Figure 54 Server with sixteen 2 5 inch hard disk drives 218 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 237: ...Figure 55 Server with twenty four 2 5 inch hard disk drives Chapter 6 Removing and replacing components 219 ...
Страница 360: ...342 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 416: ...398 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 470: ...452 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 479: ...Taiwan Class A compliance statement Notices 461 ...
Страница 480: ...462 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 487: ......
Страница 488: ... Part Number 46W8192 Printed in USA 1P P N 46W8192 ...