Table 39. IMM error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only)”, that step must be performed only by a trained
technician.
806f0813-2582ffff
An Uncorrectable
Bus Error has
occurred on system
%1. (%1 =
CIM_ComputerSystem.ElementName)
Error
A bus
uncorrectable error
has occurred.
(Sensor = PCIs)
1.
Check the system-event log.
2.
Check the PCI LED. See more
information about the PCI LED in
Light path diagnostics.
3.
Remove the adapter from the
indicated PCI slot.
4.
Check for a server firmware update.
Important:
Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code is
supported for the cluster solution
before you update the code.
5.
(Trained technician only) Replace
the system board (see Removing the
system board and Installing the
system board).
Firmware and software messages
806f000f-22010bxx
The System %1
encountered a POST
Error. (%1 =
CIM_ComputerSystem.ElementName)
Error
Firmware BIOS
(ROM) corruption
was detected
during POST.
(Sensor = ABR
Status)
1.
Make sure the server meets the
minimum configuration to start
(see Power-supply LEDs).
2.
Recover the server firmware from
the backup page:
a.
Restart the server.
b.
At the prompt, press F3 to
recover the firmware.
3.
Update the server firmware to the
latest level (see Updating the
firmware).
Important:
Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code is
supported for the cluster solution
before you update the code.
4.
Remove components one at a time,
restarting the server each time, to
see if the problem goes away.
5.
If the problem remains, (trained
technician) replace the system
board.
816f000f-22010bxx
The System %1
encountered a POST
Error deasserted. (%1
=
CIM_ComputerSystem.
ElementName)
Error
Firmware BIOS
(ROM) corruption
was deasserted
during POST.
(Sensor = ABR
Status)
No action; information only.
Appendix C. Integrated management module II (IMM2) error messages
435
Содержание 7383
Страница 1: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 8: ...vi System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 42: ...24 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 65: ...Figure 19 Server with sixteen 2 5 inch hard disk drives Chapter 2 Installing optional devices 47 ...
Страница 200: ...182 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 235: ...Figure 53 Server with eight 2 5 inch hard disk drives Chapter 6 Removing and replacing components 217 ...
Страница 236: ...Figure 54 Server with sixteen 2 5 inch hard disk drives 218 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 237: ...Figure 55 Server with twenty four 2 5 inch hard disk drives Chapter 6 Removing and replacing components 219 ...
Страница 360: ...342 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 416: ...398 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 470: ...452 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 479: ...Taiwan Class A compliance statement Notices 461 ...
Страница 480: ...462 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 487: ......