Table 39. IMM error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only)”, that step must be performed only by a trained
technician.
8107021b-0301ffff
Sensor CPU
n
QPILinkErr has
transitioned to a less
severe state from
critical. (
n
=
microprocessor
number)
Error
CPU
n
QPI link
failure detected. (
n
= microprocessor
number)
1.
Check the IBM support website for
an applicable retain tip or firmware
update that applies to this error.
2.
Inspect the microprocessor socket
for foreign material, if the
microprocessor socket contains any
foreign material, remove the foreign
material. If it is found damaged,
(trained technician only) replace the
system board (see Removing the
system board and Installing the
system board).
816f0113-0301ffff
A bus timeout has
occurred on bus CPU
n PECI. (n =
microprocessor
number)
Error
This message is for
the use case when
CPU
n
PECI bus
access error has
asserted. (
n
=
microprocessor
number)
1.
(Trained technician only) Replace
microprocessor
n
(see Removing a
microprocessor and heat sink and
Installing a microprocessor and heat
sink).
2.
If the problem persists and there is
no other CPU with the same error
indication, replace the system
board.
3.
(Trained technician only) Replace
the system board (see Removing the
system board and Installing the
system board).
(
n
= microprocessor number)
816f0a13-0301ffff
A Fatal Bus Error has
occurred on bus CPU
n PECI. (n =
microprocessor
number)
Error
This message is for
the use case when
CPU
n
PECI bus
access error has
asserted. (
n
=
microprocessor
number)
1.
(Trained technician only) Replace
microprocessor
n
(see Removing a
microprocessor and heat sink and
Installing a microprocessor and heat
sink).
2.
If the problem persists and there is
no other CPU with the same error
indication, replace the system
board.
3.
(Trained technician only) Replace
the system board (see Removing the
system board and Installing the
system board).
(
n
= microprocessor number)
Memory errors
Appendix C. Integrated management module II (IMM2) error messages
415
Содержание 7383
Страница 1: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 8: ...vi System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 42: ...24 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 65: ...Figure 19 Server with sixteen 2 5 inch hard disk drives Chapter 2 Installing optional devices 47 ...
Страница 200: ...182 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 235: ...Figure 53 Server with eight 2 5 inch hard disk drives Chapter 6 Removing and replacing components 217 ...
Страница 236: ...Figure 54 Server with sixteen 2 5 inch hard disk drives 218 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 237: ...Figure 55 Server with twenty four 2 5 inch hard disk drives Chapter 6 Removing and replacing components 219 ...
Страница 360: ...342 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 416: ...398 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 470: ...452 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 479: ...Taiwan Class A compliance statement Notices 461 ...
Страница 480: ...462 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 487: ......
Страница 488: ... Part Number 46W8192 Printed in USA 1P P N 46W8192 ...