Table 39. IMM error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only)”, that step must be performed only by a trained
technician.
80070202-1201ffff
Sensor CPU2 BRD
Fault has transitioned
to critical from a less
severe state.
Error
A sensor has
changed to Critical
state from a less
severe state for the
microprocessor 2
expansion board.
1.
Check the system-event log.
2.
Check for an error LED on the
microprocessor 2 expansion board.
3.
Replace any failing device.
4.
Check for a server firmware update.
Important:
Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code is
supported for the cluster solution
before you update the code.
5.
(Trained technician only) Replace
the microprocessor 2 expansion
board (see Removing the
microprocessor 2 expansion board
and Installing the microprocessor 2
expansion board).
80070202-1501ffff
Sensor Power PDB
Fault has transitioned
to critical from a less
severe state.
Error
A sensor has
changed to Critical
state from a less
severe state for the
power paddle card.
1.
Reseat the following components:
v
Power supply (see Removing a
hot-swap power suply and
Installing a hot-swap power
supply)
v
Power paddle card cables (see
Removing the power paddle card
and Installing the power paddle
card)
v
Power paddle card
2.
Replace the following components
one at a time, in the order shown,
restarting the server each time:
v
Power supply (see Removing a
hot-swap power suply and
Installing a hot-swap power
supply)
v
Power paddle card (see
Removing the power paddle card
and Installing the power paddle
card)
80070214-2201ffff
Sensor TPM Lock has
transitioned to a less
severe state from
critical.
Error
On production
build systems,
TPM needs to be
locked. The error is
logged when UEFI
detects TPM is not
locked on
production builds.
1.
Update the server firmware (see
Recovering the server firmware).
2.
If the problem persists, (trained
technician only) replace the system
board (see Removing the system
board and Installing the system
board).
438
System x3500 M4 Type 7383: Installation and Service Guide
Содержание 7383
Страница 1: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 8: ...vi System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 42: ...24 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 65: ...Figure 19 Server with sixteen 2 5 inch hard disk drives Chapter 2 Installing optional devices 47 ...
Страница 200: ...182 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 235: ...Figure 53 Server with eight 2 5 inch hard disk drives Chapter 6 Removing and replacing components 217 ...
Страница 236: ...Figure 54 Server with sixteen 2 5 inch hard disk drives 218 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 237: ...Figure 55 Server with twenty four 2 5 inch hard disk drives Chapter 6 Removing and replacing components 219 ...
Страница 360: ...342 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 416: ...398 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 470: ...452 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 479: ...Taiwan Class A compliance statement Notices 461 ...
Страница 480: ...462 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 487: ......
Страница 488: ... Part Number 46W8192 Printed in USA 1P P N 46W8192 ...