Table 38. DSA messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only)”, that step must be performed only by a trained
technician.
v
Go to the IBM support website at http://www.ibm.com/supportportal to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Message
number
Component Test
State
Description
Action
215-903-xxx
Optical
Drive
v
Verify
Media
Installed
v
Read/
Write Test
v
Self-Test
Messages
and actions
apply to all
three tests.
Aborted
Could not access
the drive.
1.
Insert a CD/DVD into the DVD
drive or try a new media, and wait
for 15 seconds.
2.
Run the test again.
3.
Check the drive cabling at both ends
for loose or broken connections or
damage to the cable. Replace the
cable if it is damaged.
4.
Run the test again.
5.
Make sure that the DSA code is at
the latest level.
6.
Run the test again.
7.
Replace the DVD drive.
8.
If the failure remains, go to the IBM
website for more troubleshooting
information.
215-904-xxx
Optical
Drive
v
Verify
Media
Installed
v
Read/
Write Test
v
Self-Test
Messages
and actions
apply to all
three tests.
Failed
A read error
occurred.
1.
Insert a CD/DVD into the DVD
drive or try a new media, and wait
for 15 seconds.
2.
Run the test again.
3.
Check the drive cabling at both ends
for loose or broken connections or
damage to the cable. Replace the
cable if it is damaged.
4.
Run the test again.
5.
Replace the DVD drive.
6.
If the failure remains, go to the IBM
website for more troubleshooting
information.
217-900-xxx
SAS/SATA
Hard Drive
Disk Drive
Test
Failed
1.
Reseat all hard disk drive backplane
connections at both ends.
2.
Reseat the all drives.
3.
Run the test again.
4.
Make sure that the firmware is at the
latest level.
5.
Run the test again.
6.
If the failure remains, go to the IBM
website for more troubleshooting
information.
390
System x3500 M4 Type 7383: Installation and Service Guide
Содержание 7383
Страница 1: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 8: ...vi System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 42: ...24 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 65: ...Figure 19 Server with sixteen 2 5 inch hard disk drives Chapter 2 Installing optional devices 47 ...
Страница 200: ...182 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 235: ...Figure 53 Server with eight 2 5 inch hard disk drives Chapter 6 Removing and replacing components 217 ...
Страница 236: ...Figure 54 Server with sixteen 2 5 inch hard disk drives 218 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 237: ...Figure 55 Server with twenty four 2 5 inch hard disk drives Chapter 6 Removing and replacing components 219 ...
Страница 360: ...342 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 416: ...398 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 470: ...452 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 479: ...Taiwan Class A compliance statement Notices 461 ...
Страница 480: ...462 System x3500 M4 Type 7383 Installation and Service Guide ...
Страница 487: ......
Страница 488: ... Part Number 46W8192 Printed in USA 1P P N 46W8192 ...