138
(3) I/O signal assignment
The controller's I/O port signal varies depending on the parameter No.25 setting.
[Refer to 3.8 Remote I/O Mode]
Set the parameter No.25 of MCON
Positioning mode
Teaching mode
256-point mode
0
1
2
Category
Port
No.
Symbol
Signal Name
Symbol
Signal Name
Symbol
Signal Name
0
PC1
PC1
PC1
1
PC2
PC2
PC2
2
PC4
PC4
PC4
3
PC8
PC8
PC8
4
PC16
PC16
PC16
5
PC32
Specified position No.
PC32
Specified position No.
PC32
6
–
MODE
Teaching mode
command
PC64
7
–
JISL
Jog/inching switching
PC128
Specified position No.
8
–
Unavailable
JOG+
+Jog
–
Unavailable
9
BKRL
Brake release
JOG-
-Jog
BKRL
Brake release
10
–
Unavailable
–
Unavailable
–
Unavailable
11
HOME
Home return
HOME
Home return
HOME
Home return
12
*STP
Pause
*STP
Pause
*STP
Pause
13
CSTR
Positioning start
CSTR/
PWRT
Positioning start/
Position data import
command
CSTR
Positioning start
14
RES
Reset
RES
Reset
RES
Reset
PLC output
→
MCON input
15
SON
Servo ON command
SON
Servo ON command
SON
Servo ON command
0
PM1
PM1
PM1
1
PM2
PM2
PM2
2
PM4
PM4
PM4
3
PM8
PM8
PM8
4
PM16
PM16
PM16
5
PM32
Completed position No.
PM32
Completed position No.
PM32
6
MOVE
Moving signal
MOVE
Moving signal
PM64
7
ZONE1
ZONE1
MODES
Teaching mode signal
PM128
Completed position
No.
8
(Note 1)
PZONE/
ZONE2
Position zone/
Zone 2
PZONE/
ZONE1
Position zone/
Zone 1
PZONE/
ZONE1
Position zone/
Zone 1
9
–
Unavailable
–
Unavailable
–
Unavailable
10
HEND
Home return completion
HEND
Home return
completion
HEND
Home return
completion
11
PEND
Positioning completion
signal
PEND/
WEND
Positioning completion
signal/Position data
import complete
PEND
Positioning
completion signal
12
SV
Operation preparation
end
SV
Operation preparation
completion
SV
Operation preparation
end
13
*EMGS
Emergency stop
*EMGS
Emergency stop
*EMGS
Emergency stop
14
*ALM
Alarm
*ALM
Alarm
*ALM
Alarm
MCON output
→
PLC input
15
LOAD
/TRQS
*ALML
Torque check
(Note 2)
/
Light malfunction output
*ALML
Light malfunction output
LOAD
/TRQS
*ALML
Torque check
(Note 2)
/
Light malfunction
output
Note 1 It is available to change in Parameter No. 149 Zone Output Switchover.
Note 2 It is available to change in Parameter No. 156 Torque Inspection / Light Malfunction Output Select for the pulse
motor driver.
It is the light malfunction output for the servo motor driver / brushless DC motor driver.
(Note)
“*” in codes above shows the signal of the active low. (A signal of active low is a signal that the input signal is
processed when it is turned OFF, output signal is ordinarily on while the power is ON, and turns OFF when the
signal is output.)
3.4 Fieldbus
Type
Address Map
Содержание MCON-C
Страница 1: ...MCON C CG Controller Instruction Manual Fourth Edition ...
Страница 2: ......
Страница 22: ...12 International Standards Compliances MCON with the following overseas standard RoHS Directive CE Marking UL ...
Страница 48: ...38 Chapter 1 Specifications Check ...
Страница 264: ...254 Note 1 blinking Note 2 single flash Note 3 double flash Timing of LED flashing 3 10 Fieldbus Status LEDs ...
Страница 268: ...258 3 10 Fieldbus Status LEDs ...
Страница 274: ...264 Chapter 4 Vibration Suppress Control Function ...
Страница 278: ...268 Chapter 5 Collision Detection Feature ...
Страница 284: ...274 Chapter 6 Power saving Function ...
Страница 292: ...282 Chapter 7 Absolute Reset and Absolute Battery ...
Страница 358: ...348 Chapter 9 Troubleshooting ...
Страница 368: ...358 4 TP adapter and accessories 1 TP adapter external dimensions RCB LB TGS Chapter 10 Appendix ...
Страница 474: ...Chapter 10 Appendix 464 ...
Страница 478: ......
Страница 479: ......