340
Alarm
Code
Alarm
Level
Alarm Name
Cause/Treatment
0BA
Home sensor
non-detection
Cause
: This indicates that the home-return operation of the
actuator equipped with origin sensor (option for
those except for rotary actuator) is not completed in
normal condition.
1) The work piece has interfered with the
peripherals during the home-return operation.
2) The resistance in the actuator sliding operation
is large.
3) Attachment error, malfunction or wire breakage
of origin sensor.
Treatment : If there is no interference of the work piece
confirmed with the peripherals, 2) or 3) can be
considered as a cause. Please contact IAI.
0BE
Home return timeout
Cause
: Home return does not complete after elapse of a
certain period after the start of home return.
Detailed Code
Applicable Action
01
Home Return Action Timeout
02
LS Evacuating Action Timeout
Treatment : This error does not occur in normal operation. The
combination of the controller and actuator may be
incorrect. Please contact IAI.
0C0
Actual speed excessive Cause
: This indicates the number of motor rotation
exceeded the number of allowable rotation.
1) The slide resistance of the actuator is locally high.
2) The load is increased too much due to a external
force.
With the reasons above, it can be considered a
sudden speed increase has occurred before
detecting the servo error.
Treatment : Even though this would not occur in normal
operation, check if there is any abnormality in the
parts assembly condition. Also check if there is a
possibility that an external force may be applied in
the direction of the actuator movement.
0C1
Only for
P
drivers
Operation
release
Servo error
Cause
: It indicates 2 seconds has passed without making a
move since a move command was received.
1) Connection error or wire breakage on an
actuator cable
2) Brake is not released (when equipped with a
brake).
3) Load to the motor is high due to external force.
4) The resistance in the actuator sliding operation
is large.
Treatment : 1) Check the wiring condition of the actuator
cables.
2) If an improvement can be confirmed when 24V
DC, 150mA is supplied to BKRLS terminal in the
external brake input connector, a malfunction of
the controller can be considered. Please contact
IAI.
3) Confirm that there is no error in the mechanical
part assembly condition.
4) Move the slider or the rod to a point where it
would not hit the mechanical end and reboot the
system.
Chapter 9
Troubleshooting
Содержание MCON-C
Страница 1: ...MCON C CG Controller Instruction Manual Fourth Edition ...
Страница 2: ......
Страница 22: ...12 International Standards Compliances MCON with the following overseas standard RoHS Directive CE Marking UL ...
Страница 48: ...38 Chapter 1 Specifications Check ...
Страница 264: ...254 Note 1 blinking Note 2 single flash Note 3 double flash Timing of LED flashing 3 10 Fieldbus Status LEDs ...
Страница 268: ...258 3 10 Fieldbus Status LEDs ...
Страница 274: ...264 Chapter 4 Vibration Suppress Control Function ...
Страница 278: ...268 Chapter 5 Collision Detection Feature ...
Страница 284: ...274 Chapter 6 Power saving Function ...
Страница 292: ...282 Chapter 7 Absolute Reset and Absolute Battery ...
Страница 358: ...348 Chapter 9 Troubleshooting ...
Страница 368: ...358 4 TP adapter and accessories 1 TP adapter external dimensions RCB LB TGS Chapter 10 Appendix ...
Страница 474: ...Chapter 10 Appendix 464 ...
Страница 478: ......
Страница 479: ......