294
[14] Home return offset level (Parameter No.22)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
22 Home Return Offset Level
OFST
mm
[deg]
0.00 to 9999.99
In accordance
with actuator
In this setting can set the distance from the mechanical end to the home position.
An adjustment is available for the following cases.
1) Want to match the actuator home position and the mechanical origin of the system.
2) Want to set a new home after reversing the factory-set home direction.
3) Want to eliminate a slight deviation from the previous home position generated after
replacing the actuator.
[Adjustment Process]
1) Homing execution
2) Offset check
3) Parameter setting change
4) If setting a number close to a multiple of the lead length (including home-return offset value =
0) to the home offset value, there is a possibility to servo lock on Z-phase at absolute reset,
thus the coordinates may get shifted for the lead length.
For Absolute Type, do not attempt to set a value near a number that the lead length is
multiplied by an integral number.
Have enough margin.
After the setting, repeat home return several times to confirm that the actuator always
returns to the same home position.
Caution: If the home return offset has been changed, the soft limit parameters must
also be adjusted accordingly.
In case the there is a necessity of setting a value more than the initial setting,
contact IAI.
[15] Zone boundary 2 positive side, zone boundary 2 negative side (Parameter No.23, No.24)
[Refer to 8.2 [1].]
Chapter 8 Parameter
Содержание MCON-C
Страница 1: ...MCON C CG Controller Instruction Manual Fourth Edition ...
Страница 2: ......
Страница 22: ...12 International Standards Compliances MCON with the following overseas standard RoHS Directive CE Marking UL ...
Страница 48: ...38 Chapter 1 Specifications Check ...
Страница 264: ...254 Note 1 blinking Note 2 single flash Note 3 double flash Timing of LED flashing 3 10 Fieldbus Status LEDs ...
Страница 268: ...258 3 10 Fieldbus Status LEDs ...
Страница 274: ...264 Chapter 4 Vibration Suppress Control Function ...
Страница 278: ...268 Chapter 5 Collision Detection Feature ...
Страница 284: ...274 Chapter 6 Power saving Function ...
Страница 292: ...282 Chapter 7 Absolute Reset and Absolute Battery ...
Страница 358: ...348 Chapter 9 Troubleshooting ...
Страница 368: ...358 4 TP adapter and accessories 1 TP adapter external dimensions RCB LB TGS Chapter 10 Appendix ...
Страница 474: ...Chapter 10 Appendix 464 ...
Страница 478: ......
Страница 479: ......