79
9) Zone + [mm]
(Note 2)
·········Set the coordinate value on the positive side at which position
zone output signal PZONE is turned ON. PZONE is set to ON
in the zone between this value and the coordinate value on the
negative side set in 10).
The feature follows the specified position number. It is valid
only when the position is specified but invalid in another
position operation.
10) Zone - [mm]
(Note 2)
··········Set the coordinate value on the negative side at which position
zone output signal PZONE is turned ON.
Note 2 If set to Zone + < Zone -, PZONE Signal turns ON out of the ranges of Zone + and
Zone -.
3.3 Setting of Position Data