276
LED Display for Upper Connector Axis Numbers (1
st
, 3
rd
, 5
th
and 7
th
axes)
SYS II
Driver for lower connector connection axes numbers (1
st
, 3
rd
, 5
th
and 7
th
axes)
Green Light is turned ON. : Servo ON
Red Light is turned ON. : Alarm generated, Emergency stop condition
OFF : Servo OFF
II–2
Absolute Status 1 for driver for lower connector connection axes
numbers (1, 3, 5 and 7 Axis)
The current absolute status is expressed of the patterns of the light in II
II-2 and II-1.
II–1
II–2
Green Light is turned ON. Red Light is turned ON.
Green Light is
turned ON.
Absolute reset complete Absolute reset
incomplete
Red Light is
turned ON.
Alarm generated
II–1
SYS
I II
2
1
0
2
1
0
I
II
II–0
Absolute Status 2 for driver for lower connector connection axes
numbers (1
st
, 3
rd
, 5
th
and 7
th
axes)
Green Light is turned ON. : Battery fully charged
Orange Light is turned ON. : Battery charging operation
Red Light is turned ON. : Battery disconnected
The absolute reset is to be done with using a teaching tool such as the PC software. Shown
below are the steps.
[2] Absolute reset procedure from teaching tool
1) Connect the controller with the actuator. [Refer to Chapters 1 and 2.]
2) For Simple Absolute Type, connect the absolute battery box and the controller with the
dedicated cable. [Refer to 2.2 [3] Connection of Absolute Battery]
3) Connect the teaching tool, set the operation mode setting switch on the front face of the
panel on the controller to MANU side, and then turn the power on.
4) The absolute encoder error appears on the teaching tool. Perform alarm reset.
5) Perform home-return operation at servo-ON condition. Once the home return is complete,
the point of origin is memorized at the same time the origin point is established.
In below explains the procedure using each teaching tool:
(1) For PC software
Select position data on the main screen and click the Alarm button.
Turn the servo ON with Servo button, and press Home button.
1
2
Chapter 7
Absolute Reset and
Absolute Battery
Содержание MCON-C
Страница 1: ...MCON C CG Controller Instruction Manual Fourth Edition ...
Страница 2: ......
Страница 22: ...12 International Standards Compliances MCON with the following overseas standard RoHS Directive CE Marking UL ...
Страница 48: ...38 Chapter 1 Specifications Check ...
Страница 264: ...254 Note 1 blinking Note 2 single flash Note 3 double flash Timing of LED flashing 3 10 Fieldbus Status LEDs ...
Страница 268: ...258 3 10 Fieldbus Status LEDs ...
Страница 274: ...264 Chapter 4 Vibration Suppress Control Function ...
Страница 278: ...268 Chapter 5 Collision Detection Feature ...
Страница 284: ...274 Chapter 6 Power saving Function ...
Страница 292: ...282 Chapter 7 Absolute Reset and Absolute Battery ...
Страница 358: ...348 Chapter 9 Troubleshooting ...
Страница 368: ...358 4 TP adapter and accessories 1 TP adapter external dimensions RCB LB TGS Chapter 10 Appendix ...
Страница 474: ...Chapter 10 Appendix 464 ...
Страница 478: ......
Страница 479: ......