317
[64] Light Malfunction Alarm Output Select (Parameter No.151)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
151 Light Malfunction Alarm Output
Select
FSTP
-
0: Overload
warning output
1: Message lebel
alarm output
1
If set to 0, *ALML will be generated when overload level ratio (Parameter No. 143) has been
exceeded.
If set to 1, *ALML will be generated when a message level alarm has been generated.
[65] High output setting (Parameter No.152)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
152 High Output Setting
BUEN
-
0: Disabled
1: Enabled
0 (Disabling)
Set whether use the high output function. Note that it is necessary to indicate the high-output
setting type (option) and have an actuator applicable for high-output
(Note 1)
connected.
(Note 1) High-output applicable actuator : RCP4, RCP5 Series
[66] BU velocity loop proportional gain (Parameter No.153)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
153 BU Velocity Loop Proportional
Gain
BUPC
-
1 to 10000
In accordance
with actuator
The setting in this parameter gets effective for Velocity Loop Proportional Gain when Parameter
No. 152 “High-Output Setting” is valid and No. 144 “Gain Scheduling Upper Magnification” is
set to 100 or lower.
[Refer to the 8.2 [23] Velocity loop proportional gain for the details]
Also, for the conditions to use this item, refer to “Selecting to Use Velocity Loop Proportional
Gain and Velocity Loop Integrated Gain” in the bottom of 8.2 [24].
[67] BU velocity loop integral gain (Parameter No.154)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
154 BU Velocity Loop Integral Gain
BUIC
-
1 to 100000
In accordance
with actuator
The setting in this parameter gets effective for Velocity Loop Proportional Gain when Parameter
No. 152 “High-Output Setting” is valid and No. 144 “Gain Scheduling Upper Magnification” is
set to 100 or lower.
[Refer to the 8.2 [24] Velocity loop integral gain for the details]
Also, for the conditions to use this item, refer to “Selecting to Use Velocity Loop Proportional
Gain and Velocity Loop Integrated Gain” in the bottom of 8.2 [24].
For pulse motor type only
For pulse motor type only
For pulse motor type only
Chapter 8 Parameter
Содержание MCON-C
Страница 1: ...MCON C CG Controller Instruction Manual Fourth Edition ...
Страница 2: ......
Страница 22: ...12 International Standards Compliances MCON with the following overseas standard RoHS Directive CE Marking UL ...
Страница 48: ...38 Chapter 1 Specifications Check ...
Страница 264: ...254 Note 1 blinking Note 2 single flash Note 3 double flash Timing of LED flashing 3 10 Fieldbus Status LEDs ...
Страница 268: ...258 3 10 Fieldbus Status LEDs ...
Страница 274: ...264 Chapter 4 Vibration Suppress Control Function ...
Страница 278: ...268 Chapter 5 Collision Detection Feature ...
Страница 284: ...274 Chapter 6 Power saving Function ...
Страница 292: ...282 Chapter 7 Absolute Reset and Absolute Battery ...
Страница 358: ...348 Chapter 9 Troubleshooting ...
Страница 368: ...358 4 TP adapter and accessories 1 TP adapter external dimensions RCB LB TGS Chapter 10 Appendix ...
Страница 474: ...Chapter 10 Appendix 464 ...
Страница 478: ......
Страница 479: ......