271
6.1.3 Status of positioning complete signal in selection of automatic servo OFF
Automatic servo OFF causes the actuator to be in other than the positioning complete state
due to the servo OFF. Positioning complete signal (PEND) is turned OFF. Changing the
PEND signal to the in-position signal judging whether the actuator is stopped within the
positioning width zone instead of the positioning complete signal allows PEND not to be
turned OFF during servo OFF.
This setting is reflected on complete position numbers PM1 to PM** in PIO patterns 0 to 2
confirming the positioning complete position No. or current position numbers PE* in PIO
patterns 4.
Define the setting in Parameter No.39.
Signal outputs during automatic servo OFF
Value set in
Parameter No.39
Content of PEND
signal
PEND
PM1 to PM**
PE**
0
Positioning
Completion Signal
OFF
OFF
OFF
1
In-position Signal
ON
ON
ON
(Note) SYS in the driver status LED lamps on the front panel blinks in green during the
automatic servo OFF.
[For Parameter No.39 = 0]
Operation of actuator
Positioning
operation
Automatic servo
OFF standby
Servo OFF
Positioning
operation
Servo Condition
ON
ON
OFF
ON
Completed Position No.
Output (Current position
number output)
PM1 to ** =0
(PE** = OFF)
PM1 to ** = Output
(PE** = ON)
PM1 to ** = 0
(PE** = OFF)
PM1 to ** = 0
(PE** = OFF)
Positioning Completion
Signal PEND
OFF
ON
OFF
OFF
Servo OFF Delay
Time
(Parameter No.36 to 38
[For Parameter No.39 = 1]
Operation of actuator
Positioning
operation
Automatic servo
OFF standby
Servo OFF
Positioning
operation
Servo Condition
ON
ON
OFF
ON
Completed Position No.
Output (Current position
number output)
PM1 to ** = 0
(PE** = OFF)
PM1 to ** = Output
(PE** = ON)
PM1 to ** = 0
Output
(PE** = ON)
PM1 to ** = 0
(PE** = OFF)
Positioning Completion
Signal PEND
OFF
ON
ON
OFF
Servo OFF Delay
Time
(Parameter No.36 to 38
Chapter 6 Power-saving Function
Содержание MCON-C
Страница 1: ...MCON C CG Controller Instruction Manual Fourth Edition ...
Страница 2: ......
Страница 22: ...12 International Standards Compliances MCON with the following overseas standard RoHS Directive CE Marking UL ...
Страница 48: ...38 Chapter 1 Specifications Check ...
Страница 264: ...254 Note 1 blinking Note 2 single flash Note 3 double flash Timing of LED flashing 3 10 Fieldbus Status LEDs ...
Страница 268: ...258 3 10 Fieldbus Status LEDs ...
Страница 274: ...264 Chapter 4 Vibration Suppress Control Function ...
Страница 278: ...268 Chapter 5 Collision Detection Feature ...
Страница 284: ...274 Chapter 6 Power saving Function ...
Страница 292: ...282 Chapter 7 Absolute Reset and Absolute Battery ...
Страница 358: ...348 Chapter 9 Troubleshooting ...
Страница 368: ...358 4 TP adapter and accessories 1 TP adapter external dimensions RCB LB TGS Chapter 10 Appendix ...
Страница 474: ...Chapter 10 Appendix 464 ...
Страница 478: ......
Страница 479: ......