293
[10] Current-limiting value during home return (Parameter No.13)
No.
Name
Symbol
Unit
Input Range
Default
factory setting
Type
0 to 100
Pulse Motor Type
13 Current-Limiting Value
During Home Return
ODPW
%
0 to 300
In accordance
with actuator Servo Motor Type
Brushless DC Motor Type
The setting is established for the current to suit for the standard type actuator at the delivery.
Increasing this setting will increase the home return torque.
Normally this parameter need not be changed. If the home return should be completed before
the correct position depending on the affixing method, load condition or other factors when the
actuator is used in a vertical application, the setting value must be increased. Please contact
IAI.
[11] Pause input disable selection (Parameter No.15)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
15 Pause Input Disable Selection
STP
-
0: Enabled
1: Disabled
0
This parameter defines whether the pause input signal is disabled or enabled.
If a pause operation is not needed, set the parameter to “1” and an operation becomes
available without controlling the pause signal.
Set Value
Description
0
Enabled (Use)
1
Disabled (Does not use)
[12] Home position check sensor input polarity (Parameter No.18)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
18 Home Position Check Sensor
Input Polarity
LS
-
0 to 2
In accordance
with actuator
The home sensor is an option.
Set Value
Description
0
Standard specification
(sensor not used)
1
Input is a contact
2
Input is b contact
[13] Servo ON input disable (Parameter No.21)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
21 Servo ON Input Disable Selection
SON
-
0: Enabled
1: Disabled
0
This parameter defines whether the servo ON input signal is disabled or enabled.
When the servo ON input signal is disabled, the servo is turned ON as soon as the controller
power is turned ON.
Set this parameter to “1” if servo ON/OFF is not provided.
Set Value
Description
0
Enabled (Use)
1
Disabled (Does not use)
For servo motor type and
pulse motor type only
Chapter 8 Parameter
Содержание MCON-C
Страница 1: ...MCON C CG Controller Instruction Manual Fourth Edition ...
Страница 2: ......
Страница 22: ...12 International Standards Compliances MCON with the following overseas standard RoHS Directive CE Marking UL ...
Страница 48: ...38 Chapter 1 Specifications Check ...
Страница 264: ...254 Note 1 blinking Note 2 single flash Note 3 double flash Timing of LED flashing 3 10 Fieldbus Status LEDs ...
Страница 268: ...258 3 10 Fieldbus Status LEDs ...
Страница 274: ...264 Chapter 4 Vibration Suppress Control Function ...
Страница 278: ...268 Chapter 5 Collision Detection Feature ...
Страница 284: ...274 Chapter 6 Power saving Function ...
Страница 292: ...282 Chapter 7 Absolute Reset and Absolute Battery ...
Страница 358: ...348 Chapter 9 Troubleshooting ...
Страница 368: ...358 4 TP adapter and accessories 1 TP adapter external dimensions RCB LB TGS Chapter 10 Appendix ...
Страница 474: ...Chapter 10 Appendix 464 ...
Страница 478: ......
Страница 479: ......