28
1.4.3 Specifications of PROFIBUS-DP Interface
Item
Specification
Communication Protocol
PROFIBUS-DP
Baud Rate
Automatically follows the master
Communication System
Hybrid System (Master-Slave System or Token Passing System)
Number of occupied stations
Refer to 3.4.1 PLC Address Construction by each Operation Mode
MAX. Total Network
Baud Rate
Cable Type
100m
3,000/6,000/12,000kbps
200m
1,500kbps
400m
500kbps
1000m
187.5kbps
Communication Cable Length
1200m
9.6/19.2/93.75kbps
Type A Cable
Communications Cable
STP cable AWG18
Connector
(Note 1)
9-pin female D-sub Connector
Transmission Path Format
Bus/Tree/Star
Note 1 Please prepare a 9-pin male D-sub connector for the cable-end connector.
1.4.4 Specifications of CompoNet Interface
Item
Specification
Communication System
CompoNet dedicated protocol
Communication Type
Remote I/O communication
Baud Rate
Automatically follows the master
Communication Cable Length
Follows CompoNet specifications
Slave Type
Word-Mixed Slave
Available Node Addresses for Setting 0 to 63 (Setting conducted on controller parameter)
Number of occupied channels
Refer to 3.4.1 PLC Address Construction by each Operation Mode
Communications Cable
(Note 1)
Round Cable (JIS C3306, VCTF2-core)
Flat cable I (with no sheathed)
Flat cable II (sheathed)
Connector (Controller Side)
XW7D-PB4-R (Manufactured by OMRON or equivalent)
Note 1 Prepare separately for the communication cable.
1.4.5 Specifications of EtherNet/IP Interface
Item
Specification
Communication Protocol
IEC61158 (IEEE802.3)
Baud Rate
10BASE-T/100BASE-T (Autonegotiation setting is recommended)
Communication Cable Length
Follows EtherNet/IP specifications (Distance between hub and each node: 100m
max.)
Number of Connection
Master Unit
Available Node Addresses for Setting 0.0.0.0 to 255.255.255.255
Communications Cable
(Note 1)
Category 5 or more
(Double shielded cable braided with aluminum foil recommended)
Connector
RJ45 Connector × 1pc
Note 1 Prepare separately for the communication cable.
Chapter 1 Specifications Check
Содержание MCON-C
Страница 1: ...MCON C CG Controller Instruction Manual Fourth Edition ...
Страница 2: ......
Страница 22: ...12 International Standards Compliances MCON with the following overseas standard RoHS Directive CE Marking UL ...
Страница 48: ...38 Chapter 1 Specifications Check ...
Страница 264: ...254 Note 1 blinking Note 2 single flash Note 3 double flash Timing of LED flashing 3 10 Fieldbus Status LEDs ...
Страница 268: ...258 3 10 Fieldbus Status LEDs ...
Страница 274: ...264 Chapter 4 Vibration Suppress Control Function ...
Страница 278: ...268 Chapter 5 Collision Detection Feature ...
Страница 284: ...274 Chapter 6 Power saving Function ...
Страница 292: ...282 Chapter 7 Absolute Reset and Absolute Battery ...
Страница 358: ...348 Chapter 9 Troubleshooting ...
Страница 368: ...358 4 TP adapter and accessories 1 TP adapter external dimensions RCB LB TGS Chapter 10 Appendix ...
Страница 474: ...Chapter 10 Appendix 464 ...
Страница 478: ......
Страница 479: ......